Your browser doesn't support javascript.
loading
Post-imprinting modification: electrochemical and scanning electrochemical microscopy studies of a semi-covalently surface imprinted polymer.
Kalecki, Jakub; Cieplak, Maciej; Iskierko, Zofia; Piechowska, Joanna; Nogala, Wojciech; D'Souza, Francis; Sharma, Piyush Sindhu.
Affiliation
  • Kalecki J; Institute of Physical Chemistry, Polish Academy of Sciences, Kasprzaka 44/52, 01-224 Warsaw, Poland. psharma@ichf.edu.pl.
  • Cieplak M; Institute of Physical Chemistry, Polish Academy of Sciences, Kasprzaka 44/52, 01-224 Warsaw, Poland. psharma@ichf.edu.pl.
  • Iskierko Z; Institute of Physical Chemistry, Polish Academy of Sciences, Kasprzaka 44/52, 01-224 Warsaw, Poland. psharma@ichf.edu.pl.
  • Piechowska J; Institute of Physical Chemistry, Polish Academy of Sciences, Kasprzaka 44/52, 01-224 Warsaw, Poland. psharma@ichf.edu.pl.
  • Nogala W; Institute of Physical Chemistry, Polish Academy of Sciences, Kasprzaka 44/52, 01-224 Warsaw, Poland. psharma@ichf.edu.pl.
  • D'Souza F; Department of Chemistry, University of North Texas, 1155 Union Circle No. 305070, Denton, TX 76203-5017, USA.
  • Sharma PS; Institute of Physical Chemistry, Polish Academy of Sciences, Kasprzaka 44/52, 01-224 Warsaw, Poland. psharma@ichf.edu.pl.
J Mater Chem B ; 11(8): 1659-1669, 2023 02 22.
Article in En | MEDLINE | ID: mdl-36722440
Herein we described a post-imprinting modification of the imprinted molecular cavities for electrochemical sensing of a target protein. Imprinted molecular cavities were generated by following the semi-covalent surface imprinting approach. These mesoporous cavities were modified with a ferrocene 'electrochemical' tracer for electrochemical transduction of the target protein recognition. Electrochemical sensors prepared after post-imprinting modification showed a linear response in the concentration range of 0.5 to 50 µM. Chemosensors fabricated based on capacitive impedimetric transduction demonstrated that imprinted molecular cavities without post-imprinting modification showed better selectivity. Scanning electrochemical microscopy (SECM) was used for the surface characterization of imprinted molecular cavities modified with ferrocene electrochemical tracers. SECM analysis performed in the feedback mode monitor changes in the surface state of the ferrocene-modified polymer film. The kinetics of the mediator regeneration was almost 1.8 times higher on the non-imprinted surface versus the post-imprinting modified molecular imprinted polymer.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Polymers / Molecular Imprinting Language: En Journal: J Mater Chem B Year: 2023 Document type: Article Affiliation country: Poland Country of publication: United kingdom

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Polymers / Molecular Imprinting Language: En Journal: J Mater Chem B Year: 2023 Document type: Article Affiliation country: Poland Country of publication: United kingdom