Quantification of the methodological error in kinematic evaluation of the DRUJ using dynamic CT.
Oonk, J G M; Dobbe, J G G; Strackee, S D; Strijkers, G J; Streekstra, G J.
Affiliation
  • Oonk JGM; Department of Biomedical Engineering and Physics, Amsterdam UMC, Meibergdreef 9, 1105, AZ, Amsterdam, The Netherlands. j.g.m.oonk@amsterdamumc.nl.
  • Dobbe JGG; Amsterdam Movement Sciences, Musculoskeletal Health, Restoration and Development, Amsterdam, The Netherlands. j.g.m.oonk@amsterdamumc.nl.
  • Strackee SD; Department of Biomedical Engineering and Physics, Amsterdam UMC, Meibergdreef 9, 1105, AZ, Amsterdam, The Netherlands.
  • Strijkers GJ; Amsterdam Movement Sciences, Musculoskeletal Health, Restoration and Development, Amsterdam, The Netherlands.
  • Streekstra GJ; Department of Plastic-, Reconstructive- and Handsurgery, Amsterdam UMC, Meibergdreef 9, 1105, AZ, Amsterdam, The Netherlands.
Sci Rep ; 13(1): 3159, 2023 02 23.
Article in En | MEDLINE | ID: mdl-36823242
ABSTRACT
Distal radio-ulnar joint (DRUJ) motion analysis using dynamic CT is gaining popularity. Following scanning and segmentation, 3D bone models are registered to (4D-)CT target frames. Imaging errors like low signal-to-noise ratio (SNR), limited Z-coverage and motion artefacts influence registration, causing misinterpretation of joint motion. This necessitates quantification of the methodological error. A cadaver arm and dynamic phantom were subjected to multiple 4D-CT scans, while varying tube charge-time product and phantom angular velocity, to evaluate the effects of SNR and motion artefacts on registration accuracy and precision. 4D-CT Z-coverage is limited by the scanner. To quantify the effects of different Z-coverages on registration accuracy and precision, 4D-CT was simulated by acquiring multiple spiral 3D-CT scans of the cadaver arm. Z-coverage was varied by clipping the 3D bone models prior to registration. The radius position relative to the ulna was obtained from the segmentation image. Apparent relative displacement seen in the target images is caused by registration errors. Worst-case translations were 0.45, 0.08 and 1.1 mm for SNR-, Z-coverage- and motion-related errors respectively. Worst-case rotations were 0.41, 0.13 and 6.0 degrees. This study showed that quantification of the methodological error enables composition of accurate and precise DRUJ motion scanning protocols.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Wrist Joint / Four-Dimensional Computed Tomography Limits: Humans Language: En Journal: Sci Rep Year: 2023 Document type: Article Affiliation country: Netherlands

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Wrist Joint / Four-Dimensional Computed Tomography Limits: Humans Language: En Journal: Sci Rep Year: 2023 Document type: Article Affiliation country: Netherlands