Enhanced Thromboresistance and Endothelialization of a Novel Fluoropolymer-Coated Left Atrial Appendage Closure Device.
JACC Clin Electrophysiol
; 9(8 Pt 2): 1555-1567, 2023 08.
Article
in En
| MEDLINE
| ID: mdl-37204356
ABSTRACT
BACKGROUND:
Device-related thrombus (DRT) after left atrial appendage closure (LAAC) procedures is a rare but potentially serious event. Thrombogenicity and delayed endothelialization play a role in the development of DRT. Fluorinated polymers are known to have thromboresistant properties that may favorably modulate the healing response to an LAAC device.OBJECTIVES:
The goal of this study was to compare the thrombogenicity and endothelial coverage (EC) after LAAC between the conventional uncoated WATCHMAN FLX (WM) and a novel fluoropolymer-coated WATCHMAN FLX (FP-WM).METHODS:
Canines were randomized for implantation with WM or FP-WM devices and given no postimplant antithrombotic/antiplatelet agents. The presence of DRT was monitored by using transesophageal echocardiography and verified histologically. The biochemical mechanisms associated with coating were assessed by using flow loop experiments to quantify albumin adsorption, platelet adhesion, and porcine implants to quantify EC and the expression of markers of endothelial maturation (ie, vascular endothelial-cadherin/p120-catenin).RESULTS:
Canines implanted with FP-WM exhibited significantly less DRT at 45 days than those implanted with WM (0% vs 50%; P < 0.05). In vitro experiments showed significantly greater albumin adsorption (52.8 [IQR 41.0-58.3] mm2 vs 20.6 [IQR 17.2-26.6] mm2; P = 0.03) and significantly less platelet adhesion (44.7% [IQR 27.2%-60.2%] vs 60.9% [IQR 39.9%-70.1%]; P < 0.01) on FP-WM. Porcine implants showed significantly greater EC by scanning electron microscopy (87.7% [IQR 83.4%-92.3%] vs 68.2% [IQR 47.6%-72.8%]; P = 0.03), and higher vascular endothelial-cadherin/p120-catenin expression after 3 months on FP-WM compared with WM.CONCLUSIONS:
The FP-WM device showed significantly less thrombus and reduced inflammation in a challenging canine model. Mechanistic studies indicated that the fluoropolymer-coated device binds more albumin, leading to reduced platelet binding, less inflammation, and greater EC.Key words
Full text:
1
Collection:
01-internacional
Database:
MEDLINE
Main subject:
Atrial Fibrillation
/
Thrombosis
/
Atrial Appendage
Type of study:
Clinical_trials
Limits:
Animals
Language:
En
Journal:
JACC Clin Electrophysiol
Year:
2023
Document type:
Article
Affiliation country:
United States