Your browser doesn't support javascript.
loading
Assessment of Microhardness of Conventional and Bulk-Fill Resin Composites Using Different Light-Curing Intensity.
Jakupovic, Selma; Pervan, Nedim; Mesic, Elmedin; Gavranovic-Glamoc, Alma; Bajsman, Anita; Muratovic, Enis; Kazazic, Lejla; Kantardzic-Kovacevic, Alma.
Affiliation
  • Jakupovic S; Department of Restorative Dentistry and Endodontics, Faculty of Dentistry with Clinics, University of Sarajevo, 71000 Sarajevo, Bosnia and Herzegovina.
  • Pervan N; Department of Mechanical Design, Faculty of Mechanical Engineering, University of Sarajevo, 71000 Sarajevo, Bosnia and Herzegovina.
  • Mesic E; Department of Mechanical Design, Faculty of Mechanical Engineering, University of Sarajevo, 71000 Sarajevo, Bosnia and Herzegovina.
  • Gavranovic-Glamoc A; Department of Prosthodontics, Faculty of Dentistry with Clinics, University of Sarajevo, 71000 Sarajevo, Bosnia and Herzegovina.
  • Bajsman A; Department of Dental Morphology with Dental Anthropology and Forensics, Faculty of Dentistry with Clinics, University of Sarajevo, 71000 Sarajevo, Bosnia and Herzegovina.
  • Muratovic E; Department of Mechanical Design, Faculty of Mechanical Engineering, University of Sarajevo, 71000 Sarajevo, Bosnia and Herzegovina.
  • Kazazic L; Department of Prosthodontics, Faculty of Dentistry with Clinics, University of Sarajevo, 71000 Sarajevo, Bosnia and Herzegovina.
  • Kantardzic-Kovacevic A; Faculty of Dentistry with Clinics, University of Sarajevo, 71000 Sarajevo, Bosnia and Herzegovina.
Polymers (Basel) ; 15(10)2023 May 10.
Article in En | MEDLINE | ID: mdl-37242825
(1) Background: This study evaluates the effect of a conventional/low-voltage light-curing protocol (LV protocol) (10 s with 1340 mW/cm2) and high-voltage light-curing protocol (HV protocol) (3 s with 3440 mW/cm2) on the microhardness (MH) of dental resin-based composites (RBCs). Five resin composites were tested: conventional Evetric (EVT), Tetric Prime (TP), Tetric Evo Flow (TEF), bulk-fill Tetric Power Fill (PFL), and Tetric Power Flow (PFW). (2) Materials and Methods: Two tested composites (PFW and PFL) were designed for high-intensity light curing. The samples were made in the laboratory in specially designed cylindrical molds; diameter = 6 mm and height = 2 or 4 mm, depending on the type of composite. Initial MH was measured on the top and bottom surfaces of composite specimens 24 h after light curing using a digital microhardness tester (QNESS 60 M EVO, ATM Qness GmbH, Mammelzen, Germany). The correlation between the filler content (wt%, vol%) and the MH of the RBCs was tested. For the calculation of depth-dependent curing effectiveness, the bottom/top ratio for initial MH was used. (3) Conclusions: MH of RBCs is more dependent on material composition than on light-curing protocol. Filler wt% has a greater influence on MH values compared to filler vol%. The bottom/top ratio showed values over 80% for bulk composites, while for conventional sculptable composites, borderline or suboptimal values were measured for both curing protocols.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Polymers (Basel) Year: 2023 Document type: Article Country of publication: Switzerland

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Polymers (Basel) Year: 2023 Document type: Article Country of publication: Switzerland