Your browser doesn't support javascript.
loading
Donor lamella thickness after ultrathin Descemet stripping automated endothelial keratoplasty and its relation to postoperative visual acuity and pre-operative lamella measures.
van Rooij, Jeroen; Engel, Angela; Steijger-Vermaat, Petra; Molenaar, Annemieke; Vigueras-Guillén, Juan Pedro; Wubbels, René J.
Affiliation
  • van Rooij J; Rotterdam Eye Hospital, Schiedamse Vest 180, Rotterdam, 3011 BH, The Netherlands.
  • Engel A; Rotterdam Ophthalmic Institute, Schiedamse Vest 160, Rotterdam, 3011 BH, The Netherlands.
  • Steijger-Vermaat P; Cornea Department, ETB-BISLIFE, Markt 58, Beverwijk, 1941 BM, The Netherlands.
  • Molenaar A; Cornea Department, ETB-BISLIFE, Markt 58, Beverwijk, 1941 BM, The Netherlands.
  • Vigueras-Guillén JP; Rotterdam Ophthalmic Institute, Schiedamse Vest 160, Rotterdam, 3011 BH, The Netherlands.
  • Wubbels RJ; Rotterdam Ophthalmic Institute, Schiedamse Vest 160, Rotterdam, 3011 BH, The Netherlands. r.wubbels@oogziekenhuis.nl.
BMC Ophthalmol ; 23(1): 265, 2023 Jun 12.
Article in En | MEDLINE | ID: mdl-37308898
ABSTRACT

BACKGROUND:

To accurately measure ultrathin Descemet stripping automated endothelial keratoplasty (DSAEK) donor lamella thickness during the first postoperative year and to correlate this with pre-operative and other postoperative measurements.

METHODS:

Donor lamella thickness in 41 eyes undergoing DSAEK for Fuchs endothelial dystrophy (FED) was measured using the Tomey Casia OCT directly after graft preparation and at 1 week and 1, 3, 6 and 12 months postoperatively. Visual acuity and endothelial cell density were measured as the secondary parameters.

RESULTS:

Individual graft thickness profiles were shown to be fairly regular within the optically relevant area. There was a strong and highly significant correlation between the pre- and postoperative lamellar thicknesses at all time points (p < 0.0001). Compared with the measurements directly after preparation at the cornea bank, the lamella thickness decreased by 12% after 12 months. Between 1 and 12 months postoperatively, the lamella thickness (mean ± SD) changed from 112 ± 27 µm to 101 ± 21 µm. Best spectacle-corrected visual acuity (BSCVA) changed from 0.46 ± 0.30 logMAR pre-operatively through 0.36 ± 0.33 at 1 month to 0.13 ± 0.16 at 1 year postoperatively. The endothelial cell counts were comparable to those reported in previous studies.

CONCLUSIONS:

Thickness profiles of individual grafts were fairly regular within the optically relevant area. A strong relationship between pre- and postoperative graft thicknesses was detected, and ultrathin DSAEK grafts prepared using methods similar to that applied in this study are expected to show a deswelling of around 12% during the first postoperative year. No correlation was detected between graft thickness and BSCVA.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Fuchs&apos; Endothelial Dystrophy / Corneal Transplantation Limits: Humans Language: En Journal: BMC Ophthalmol Journal subject: OFTALMOLOGIA Year: 2023 Document type: Article Affiliation country: Netherlands

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Fuchs&apos; Endothelial Dystrophy / Corneal Transplantation Limits: Humans Language: En Journal: BMC Ophthalmol Journal subject: OFTALMOLOGIA Year: 2023 Document type: Article Affiliation country: Netherlands