Your browser doesn't support javascript.
loading
Fine-Tuning the Characteristic of the Applied Potential To Improve AC-iEK Separations of Microparticles.
Ahamed, Nuzhet Nihaar Nasir; Mendiola-Escobedo, Carlos A; Ernst, Olivia D; Perez-Gonzalez, Victor H; Lapizco-Encinas, Blanca H.
Affiliation
  • Ahamed NNN; Microscale Bioseparations Laboratory and Biomedical Engineering Department, Rochester Institute of Technology, 160 Lomb Memorial Drive, Rochester, New York 14623, United States.
  • Mendiola-Escobedo CA; School of Engineering and Sciences, Tecnologico de Monterrey, Monterrey, Nuevo Leon 64849, Mexico.
  • Ernst OD; Microscale Bioseparations Laboratory and Biomedical Engineering Department, Rochester Institute of Technology, 160 Lomb Memorial Drive, Rochester, New York 14623, United States.
  • Perez-Gonzalez VH; School of Engineering and Sciences, Tecnologico de Monterrey, Monterrey, Nuevo Leon 64849, Mexico.
  • Lapizco-Encinas BH; Microscale Bioseparations Laboratory and Biomedical Engineering Department, Rochester Institute of Technology, 160 Lomb Memorial Drive, Rochester, New York 14623, United States.
Anal Chem ; 95(26): 9914-9923, 2023 Jul 04.
Article in En | MEDLINE | ID: mdl-37342914
ABSTRACT
There is an immediate need for the development of rapid and reliable methods for microparticle and cell assessments, and electrokinetic (EK) phenomena can be exploited to meet that need in a low cost and label-free fashion. The present study combines modeling and experimentation to separate a binary mixture of microparticles of the same size (5.1 µm), shape (spherical), and substrate material (polystyrene), but with a difference in particle zeta potentials of only ∼14 mV, by applying direct current (DC)-biased low-frequency alternating current (AC) voltages in an insulator-based-EK (iEK) system. Four distinct separations were carried out to systematically study the effect of fine-tuning each of the three main characteristics of the applied voltage frequency, amplitude, and DC bias. The results indicate that fine-tuning each parameter improved the separation from an initial separation resolution Rs = 0.5 to a final resolution Rs = 3.1 of the fully fine-tuned separation. The separation method exhibited fair reproducibility in retention time with variations ranging from 6 to 26% between experimental repetitions. The present study demonstrates the potential to extend the limits of iEK systems coupled with carefully fine-tuned DC-biased low-frequency AC voltages to perform discriminatory micron-sized particle separations.

Full text: 1 Collection: 01-internacional Database: MEDLINE Type of study: Prognostic_studies Language: En Journal: Anal Chem Year: 2023 Document type: Article Affiliation country: United States

Full text: 1 Collection: 01-internacional Database: MEDLINE Type of study: Prognostic_studies Language: En Journal: Anal Chem Year: 2023 Document type: Article Affiliation country: United States