GC Analysis of Metformin, Ranitidine and Famotidine from Pharmaceuticals and Human Serum.
Zounr, Rizwan A; Khuhawar, Muhammad Y; Khuhawar, Taj M J; Lanjwani, Muhammad F; Khuhawar, Muzamil Y.
Affiliation
  • Zounr RA; Institute of Advanced Research Studies in Chemical Sciences, University of Sindh, Jamshoro 76080, Sindh, Pakistan.
  • Khuhawar MY; Institute of Advanced Research Studies in Chemical Sciences, University of Sindh, Jamshoro 76080, Sindh, Pakistan.
  • Khuhawar TMJ; Institute of Advanced Research Studies in Chemical Sciences, University of Sindh, Jamshoro 76080, Sindh, Pakistan.
  • Lanjwani MF; Dr. M.A. Kazi Institute of Chemistry, University of Sindh, Jamshoro 76080, Sindh, Pakistan.
  • Khuhawar MY; Abbott Pharmaceutical Company in Korangi, Landhi Karachi 75106, Sindh, Pakistan.
J Chromatogr Sci ; 61(9): 807-813, 2023 Nov 05.
Article in En | MEDLINE | ID: mdl-37415425
ABSTRACT
A method has been designed based on gas chromatography with flame ionization detection (FID) for the separation and analyses of ranitidine, famotidine and metformin after pre-column derivatization with trifluoroacetylacetone and ethyl chloroformate. DB-1 (30 m × 0.32 mm id) column with film thickness 0.25 µm was used for the separation at an initial temperature of column was 100°C for 2 min, and ramping at 20°C/min up to 250°C, with a hold time of 3 min. The rate of nitrogen flow was 2.5 mL/min and FID was used for detection. Complete separation was obtained between all the three drugs including excess of derivatization reagents. Linear calibration curves and detection limits were obtained in the ranges 0.1-30 µg/mL and 0.011-0.015 µg/mL. The procedure was repeatable in terms of peak heights/peak areas and retention time (n = 5) for derivatization, quantitation and separation with relative standard deviations (RSDs) within 2.0-3.0%. The approach was examined for the analyses of drug products and serum after the intake of the drugs by healthy volunteers, and recoveries were obtained within 95-98% with RSDs 2.4-3.1%.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Famotidine / Metformin Limits: Humans Language: En Journal: J Chromatogr Sci Year: 2023 Document type: Article Affiliation country: Pakistan