Your browser doesn't support javascript.
loading
Hyperoxia-induced deterioration of diastolic function in anaesthetised patients with coronary artery disease - Randomised crossover trial.
Friess, Jan O; Mikasi, Jan; Baumann, Rico; Ranjan, Rajevan; Fischer, Kady; Levis, Anja; Terbeck, Sandra; Hirschi, Trevor; Gerber, Daniel; Erdoes, Gabor; Schoenhoff, Florian S; Carrel, Thierry P; Madhkour, Raouf; Eberle, Balthasar; Guensch, Dominik P.
Affiliation
  • Friess JO; Department of Anaesthesiology and Pain Medicine, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.
  • Mikasi J; Department of Anesthesiology, Critical Care and Pain Medicine, Boston Children's Hospital, Harvard Medical School, Boston, MA, USA.
  • Baumann R; Department of Anaesthesiology and Pain Medicine, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.
  • Ranjan R; Department of Anaesthesiology and Pain Medicine, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.
  • Fischer K; Department of Anaesthesiology and Pain Medicine, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.
  • Levis A; Department of Anaesthesiology and Pain Medicine, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.
  • Terbeck S; Department of Anaesthesiology and Pain Medicine, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.
  • Hirschi T; Department of Anaesthesiology and Pain Medicine, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.
  • Gerber D; Department of Anaesthesiology and Pain Medicine, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.
  • Erdoes G; Department of Anaesthesiology and Pain Medicine, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.
  • Schoenhoff FS; Department of Anaesthesiology and Pain Medicine, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.
  • Carrel TP; Department of Cardiovascular Surgery, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.
  • Madhkour R; Department of Cardiovascular Surgery, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.
  • Eberle B; Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.
  • Guensch DP; Department of Anaesthesiology and Pain Medicine, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.
BJA Open ; 6: 100135, 2023 Jun.
Article in En | MEDLINE | ID: mdl-37588173
ABSTRACT

Background:

There are no current recommendations for oxygen titration in patients with stable coronary artery disease. This study investigates the effect of iatrogenic hyperoxia on cardiac function in patients with coronary artery disease undergoing general anaesthesia.

Methods:

Patients scheduled for elective coronary artery bypass graft surgery were prospectively recruited into this randomised crossover clinical trial. All patients were exposed to inspired oxygen fractions of 0.3 (normoxaemia) and 0.8 (hyperoxia) in randomised order. A transoesophageal echocardiographic imaging protocol was performed during each exposure. Primary analysis investigated changes in 3D peak strain, whereas secondary analyses investigated other systolic and diastolic responses.

Results:

There was no statistical difference in systolic function between normoxaemia and hyperoxia. However, the response in systolic function to hyperoxia was dependent on ventricular function at normoxaemia. Patients with a normoxaemic left ventricular (LV) global longitudinal strain (GLS) poorer than the derived cut-off (>-15.4%) improved with hyperoxia (P<0.01), whereas in patients with normoxaemic LV-GLS <-15.4%, LV-GLS worsened with transition to hyperoxia (P<0.01). The same was seen for right ventricular GLS with a cut-off at -24.1%. Diastolic function worsened during hyperoxia indicated by a significant increase of averaged E/e' (8.6 [2.6]. vs 8.2 [2.4], P=0.01) and E/A ratio (1.4 (0.4) vs 1.3 (0.4), P=0.01).

Conclusions:

Although the response of biventricular systolic variables is dependent on systolic function at normoxaemia, diastolic function consistently worsens under hyperoxia. In coronary artery disease, intraoperative strain analysis may offer guidance for oxygen titration. Clinical trial registration NCT04424433.