Your browser doesn't support javascript.
loading
Socket shield technique: Stress distribution analysis.
Neves, Ricardo Guimarães; Lazari-Carvalho, Priscilla Cardoso; Carvalho, Marco Aurélio; Carvalho, Alexandre Leite; de Souza, João Batista; Torres, Érica Miranda.
Affiliation
  • Neves RG; Private Practice, Goiânia, GO, Brazil.
  • Lazari-Carvalho PC; Department of Oral Rehabilitation, School of Dentistry, Evangelical University of Goias, Anápolis, GO, Brazil.
  • Carvalho MA; Department of Oral Rehabilitation, School of Dentistry, Evangelical University of Goias, Anápolis, GO, Brazil.
  • Carvalho AL; Private Practice, Goiânia, GO, Brazil.
  • de Souza JB; Department of Restorative Dentistry, School of Dentistry, Federal University of Goiás, Goiânia, GO, Brazil.
  • Torres ÉM; Department of Oral Rehabilitation, School of Dentistry, Federal University of Goiás, Goiânia, GO, Brazil.
J Indian Soc Periodontol ; 27(4): 392-398, 2023.
Article in En | MEDLINE | ID: mdl-37593548
ABSTRACT

Background:

To analyze through finite element analysis the stress distribution in peri-implant bone tissues, implants, and prosthetic components induced by the socket shield (SS) technique in comparison to other techniques used to treat tooth loss. Materials and

Methods:

A three-dimensional model of a superior central incisor crown supported by implant was modeled and three different placement conditions were simulated SS - 2.0-mm-thick root dentin fragment positioned between the alveolar buccal wall and implant; heterologous bone graft (HBG) - bovine bone graft positioned the alveolar buccal wall and implant; and control (C) - implant fully placed in bone tissue of a healed alveolus. The model was restricted at the lateral surfaces of the bone tissue and the following loads were simulated Both oblique (45°) loads of 100 N on the lingual surface of the crown (maximal habitual intercuspation) and 25.5 N on the incisal edge of the crown (tooth contact during mandibular protrusion) were simultaneously applied. Tensile stress, shear stress, compression, and displacement were analyzed in the cortical bone, trabecular bone, dentin root fragment, and bone graft; while equivalent von Mises stresses were quantified in the implant and prosthetic components.

Results:

Stress values of SS and HBG in the bone tissues were higher than C, while slight differences within models were observed for dentin root fragment, bone graft, implant, and prosthetic components.

Conclusions:

The SS technique presented the highest stress concentration in the peri-implant tissues.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: J Indian Soc Periodontol Year: 2023 Document type: Article Affiliation country: Brazil

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: J Indian Soc Periodontol Year: 2023 Document type: Article Affiliation country: Brazil