Your browser doesn't support javascript.
loading
Topologically optimized magnetic lens for magnetic resonance applications.
Wadhwa, Sagar; Jouda, Mazin; Deng, Yongbo; Nassar, Omar; Mager, Dario; Korvink, Jan G.
Affiliation
  • Wadhwa S; Institute of Microstructure Technology, Karlsruhe Institute of Technology, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Germany.
  • Jouda M; Institute of Microstructure Technology, Karlsruhe Institute of Technology, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Germany.
  • Deng Y; State Key Laboratory of Applied Optics (SKLAO), Changchun Institute of Optics, Fine Mechanics and Physics (CIOMP), Chinese Academy of Sciences, Dongnanhu Road 3888, Changchun 130033, China.
  • Nassar O; Institute of Microstructure Technology, Karlsruhe Institute of Technology, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Germany.
  • Mager D; Institute of Microstructure Technology, Karlsruhe Institute of Technology, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Germany.
  • Korvink JG; Institute of Microstructure Technology, Karlsruhe Institute of Technology, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Germany.
Magn Reson (Gott) ; 1(2): 225-236, 2020.
Article in En | MEDLINE | ID: mdl-37904821
ABSTRACT
Improvements to the signal-to-noise ratio of magnetic resonance detection lead to a strong reduction in measurement time, yet as a sole optimization goal for resonator design, it would be an oversimplification of the problem at hand. Multiple constraints, for example for field homogeneity and sample shape, suggest the use of numerical optimization to obtain resonator designs that deliver the intended improvement. Here we consider the 2D Lenz lens to be a sufficiently broadband flux transforming interposer between the sample and a radiofrequency (RF) circuit and to be a flexible and easily manufacturable device family with which to mediate different design requirements. We report on a method to apply topology optimization to determine the optimal layout of a Lenz lens and demonstrate realizations for both low- (45 MHz) and high-frequency (500 MHz) nuclear magnetic resonance.

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Magn Reson (Gott) Year: 2020 Document type: Article Affiliation country: Germany Publication country: ALEMANHA / ALEMANIA / DE / DEUSTCHLAND / GERMANY

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Magn Reson (Gott) Year: 2020 Document type: Article Affiliation country: Germany Publication country: ALEMANHA / ALEMANIA / DE / DEUSTCHLAND / GERMANY