Administered dosage and effective dose estimated from 81Rb-rubidium hydroxide for lung ventilation scintigraphy using 81mKr noble gas.
Kamiya, Takashi; Iimori, Takashi; Maeda, Yukito; Yada, Nobuhiro; Hayashi, Naoya; Iguchi, Harumi; Narita, Masataka.
Affiliation
  • Kamiya T; Department of Medical Technology, Osaka University Hospital, Suita 5650871, Japan.
  • Iimori T; Department of Radiology, Chiba University Hospital, Chiba 2608677, Japan.
  • Maeda Y; Department of Clinical Radiology, Kagawa University Hospital, Kita-gun 7610793, Japan.
  • Yada N; Department of Radiology, Shimane University Hospital, Izumo 6938501, Japan.
  • Hayashi N; Department of Medical Technology, Kochi Medical School Hospital, Nankoku 7830043, Japan.
  • Iguchi H; Department of Radiology, Shiga University of Medical Science Hospital, Otsu 5202192, Japan.
  • Narita M; Department of Radiology, Hirosaki University Hospital, Hirosaki 0368563, Japan.
Radiat Prot Dosimetry ; 200(2): 149-154, 2024 Feb 16.
Article in En | MEDLINE | ID: mdl-37987214
ABSTRACT
The aim of this study was to estimate the administered dosage of 81mKr noble gas as calculated by the radioactivity of 81Rb-rubidium hydroxide (81RbOH). The administered dosage was regarded as the total amount of 81mKr noble gas. The radioactivity of 81mKr was calculated using the radioactivity of 81RbOH at the examination, the beginning of inhalation, the inhalation duration and the attenuation volume from the generator to the patient for 81mKr noble gas. In addition, we created an Internet survey and asked National University Hospital in Japan to respond to questions regarding the parameters of concern. Survey responses were provided by 38 hospitals (response rate was 90.5%). Twenty-seven hospitals (64.3%) examined lung ventilation scintigraphy using 81mKr noble gas. The mean administered dosage and the effective dose of lung ventilation scintigraphy using 81mKr noble gas were 35.8 ± 22.1 GBq and 0.97 ± 0.60 mSv, respectively.