Your browser doesn't support javascript.
loading
Intrinsic variability of fluorescence calibrators impacts the assignment of MESF or ERF values to nanoparticles and extracellular vesicles by flow cytometry.
Lozano-Andrés, Estefanía; Van Den Broeck, Tina; Wang, Lili; Mehrpouyan, Majid; Tian, Ye; Yan, Xiaomei; Arkesteijn, Ger J A; Wauben, Marca H M.
Affiliation
  • Lozano-Andrés E; Department of Biomolecular Health Sciences, Faculty of Veterinary Medicine, Utrecht University, Utrecht, the Netherlands. Electronic address: e.lozanoandres@uu.nl.
  • Van Den Broeck T; BD Biosciences, Erembodegem, Belgium.
  • Wang L; Biosystems and Biomaterials Division, National Institutes of Standards and Technology (NIST), Gaithersburg, MD 20899, United States of America.
  • Mehrpouyan M; BD Biosciences, San Jose, CA 95131, United States of America.
  • Tian Y; Department of Chemical Biology, MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, Key Laboratory for Chemical Biology of Fujian Province, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, People's Republic of China.
  • Yan X; Department of Chemical Biology, MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, Key Laboratory for Chemical Biology of Fujian Province, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, People's Republic of China.
  • Arkesteijn GJA; Department of Biomolecular Health Sciences, Faculty of Veterinary Medicine, Utrecht University, Utrecht, the Netherlands.
  • Wauben MHM; Department of Biomolecular Health Sciences, Faculty of Veterinary Medicine, Utrecht University, Utrecht, the Netherlands.
Nanomedicine ; 56: 102720, 2024 Feb.
Article in En | MEDLINE | ID: mdl-38007067
Flow cytometry allows to characterize nanoparticles (NPs) and extracellular vesicles (EVs) but results are often expressed in arbitrary units of fluorescence. We evaluated the precision and accuracy of molecules of equivalent soluble fluorophores (MESF) beads for calibration of NPs and EVs. Firstly, two FITC-MESF bead sets, 2 and 6 um in size, were measured on three flow cytometers. We showed that arbitrary units could not be compared between instruments but after calibration, comparable FITC MESF units were achieved. However, the two calibration bead sets displayed varying slopes that were consistent across platforms. Further investigation revealed that the intrinsic uncertainty related to the MESF beads impacts the robust assignment of values to NPs and EVs based on extrapolation into the dim fluorescence range. Similar variations were found with PE MESF calibration. Therefore, the same calibration materials and numbers of calibration points should be used for reliable comparison of submicron sized particles.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Nanoparticles / Extracellular Vesicles Language: En Journal: Nanomedicine Journal subject: BIOTECNOLOGIA Year: 2024 Document type: Article Country of publication: United States

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Nanoparticles / Extracellular Vesicles Language: En Journal: Nanomedicine Journal subject: BIOTECNOLOGIA Year: 2024 Document type: Article Country of publication: United States