Your browser doesn't support javascript.
loading
A Physical Fatigue Evaluation Method for Automotive Manual Assembly: An Experiment of Cerebral Oxygenation with ARE Platform.
Mao, Wanting; Yang, Xiaonan; Wang, Chaoran; Hu, Yaoguang; Gao, Tianxin.
Affiliation
  • Mao W; Department of Civil and Environmental Engineering, Imperial College London, London SW7 2AZ, UK.
  • Yang X; School of Mechanical Engineering, Beijing Institute of Technology, Beijing 100081, China.
  • Wang C; Key Laboratory of Industry Knowledge & Data Fusion Technology and Application, Ministry of Industry and Information Technology, Beijing Institute of Technology, Beijing 100081, China.
  • Hu Y; Yangtze Delta Region Academy, Beijing Institute of Technology, Jiaxing 314019, China.
  • Gao T; School of Mechanical Engineering, Beijing Institute of Technology, Beijing 100081, China.
Sensors (Basel) ; 23(23)2023 Nov 26.
Article in En | MEDLINE | ID: mdl-38067783
Due to the complexity of the automobile manufacturing process, some flexible and delicate assembly work relies on manual operations. However, high-frequency and high-load repetitive operations make assembly workers prone to physical fatigue. This study proposes a method for evaluating human physical fatigue for the manual assembly of automobiles with methods: NIOSH (National Institute for Occupational Safety and Health), OWAS (Ovako Working Posture Analysis System) and RULA (Rapid Upper Limb Assessment). The cerebral oxygenation signal is selected as an objective physiological index reflecting the human fatigue level to verify the proposed physical fatigue evaluation method. Taking auto seat assembly and automobile manual assembly as an example, 18 group experiments were carried out with the ARE platform (Augmented Reality-based Ergonomic Platform). Furthermore, predictions of metabolic energy expenditure were performed for experiments in Tecnomatix Jack. Finally, it is concluded that the proposed physical fatigue evaluation method can reflect the human physical fatigue level and is more accurate than the evaluation of metabolic energy consumption in Tecnomatix Jack because of the immersion that comes with the AR devices and the precision that comes with motion capture devices.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Occupational Health / Occupational Diseases Limits: Humans Country/Region as subject: America do norte Language: En Journal: Sensors (Basel) Year: 2023 Document type: Article Country of publication: Switzerland

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Occupational Health / Occupational Diseases Limits: Humans Country/Region as subject: America do norte Language: En Journal: Sensors (Basel) Year: 2023 Document type: Article Country of publication: Switzerland