Bonding Strength of Various Luting Agents between Zirconium Dioxide Crowns and Titanium Bonding Bases after Long-Term Artificial Chewing.
Bagegni, Aimen; Borchers, Justus; Beisel, Samuel; Patzelt, Sebastian B M; Vach, Kirstin; Kohal, Ralf.
Affiliation
  • Bagegni A; Department of Prosthetic Dentistry, Center for Dental Medicine, Medical Center-University of Freiburg, Faculty of Medicine, University of Freiburg, Hugstetter Street 55, 79106 Freiburg, Germany.
  • Borchers J; Mydent Medical Care Center, Krefelder Street 15-17, 41460 Neuss, Germany.
  • Beisel S; Department of Prosthetic Dentistry, Center for Dental Medicine, Medical Center-University of Freiburg, Faculty of Medicine, University of Freiburg, Hugstetter Street 55, 79106 Freiburg, Germany.
  • Patzelt SBM; Department of Sustainable Systems Engineering, Walter-and-Ingeborg-Herrmann-Chair for Power Ultrasonics and Engineering of Functional Materials, Faculty of Engineering, University of Freiburg, Emmy-Noether-Street 2, 79110 Freiburg, Germany.
  • Vach K; Department of Prosthetic Dentistry, Center for Dental Medicine, Medical Center-University of Freiburg, Faculty of Medicine, University of Freiburg, Hugstetter Street 55, 79106 Freiburg, Germany.
  • Kohal R; Private Dental Clinic, Am Dorfplatz 3, 78658 Zimmern ob Rottweil, Germany.
Materials (Basel) ; 16(23)2023 Nov 24.
Article in En | MEDLINE | ID: mdl-38068058
ABSTRACT
The use of hybrid abutment crowns bonded extraorally to a titanium bonding base has aesthetic and biological benefits for the prosthetic rehabilitation of oral implants. The objective of this study was to evaluate the effects of luting agents between a zirconium dioxide crown and the titanium bonding base on crown/abutment retention and the subsequent durability of the prosthetic superstructure. Fifty-six implant abutment samples, all restored with a lower first premolar zirconium dioxide crown, were used and divided into seven groups (n = 8/group) according to the type of luting agent used group 1, SpeedCEM Plus; group 2, Panavia SA Cement Universal; group 3, Panavia V5; group 4, RelyX Unicem 2 Automix; group 5, VITA ADIVA IA-Cem; group 6, Ketac CEM; and group 7, Hoffmann's Phosphate Cement. All specimens were subjected to thermomechanical loading (load of 49 N, 5 million chewing cycles and 54.825 thermocycles in water with temperatures of 5 °C and 55 °C). The surviving samples were exposed to a pull-off force until crown debonding from the bonding base. Overall, 55 samples survived the thermomechanical load. Group 2 showed the highest mean pull-off force value (762 N), whereas group 6 showed the lowest mean value (55 N). The differences between the seven groups were statistically significant (ANOVA, p < 0.001). The debonding failure pattern was mainly adhesive and was noticed predominantly at the zirconium dioxide-luting agent interface. Within the scope of the present investigation, it was shown that most of the luting agents are suitable for "cementation" of a zirconium dioxide crown onto a titanium base since the debonding forces are above a recommended value (159 N).
Key words