No difference in patient reported outcome and inflammatory response after coated and uncoated total knee arthroplasty - a randomized controlled study.
Tille, Eric; Beyer, Franziska; Lützner, Cornelia; Postler, Anne; Thomas, Peter; Summer, Burkhard; Lützner, Jörg.
Affiliation
  • Tille E; University Center of Orthopaedic, Trauma and Plastic Surgery, University Hospital Carl Gustav Carus, TU Dresden, Fetscherst. 74, 01307, Dresden, Germany. eric.tille@gmail.com.
  • Beyer F; University Center of Orthopaedic, Trauma and Plastic Surgery, University Hospital Carl Gustav Carus, TU Dresden, Fetscherst. 74, 01307, Dresden, Germany.
  • Lützner C; University Center of Orthopaedic, Trauma and Plastic Surgery, University Hospital Carl Gustav Carus, TU Dresden, Fetscherst. 74, 01307, Dresden, Germany.
  • Postler A; University Center of Orthopaedic, Trauma and Plastic Surgery, University Hospital Carl Gustav Carus, TU Dresden, Fetscherst. 74, 01307, Dresden, Germany.
  • Thomas P; Department of Dermatology und Allergology, Ludwig-Maximilians-University, Munich, Germany.
  • Summer B; Department of Dermatology und Allergology, Ludwig-Maximilians-University, Munich, Germany.
  • Lützner J; University Center of Orthopaedic, Trauma and Plastic Surgery, University Hospital Carl Gustav Carus, TU Dresden, Fetscherst. 74, 01307, Dresden, Germany.
BMC Musculoskelet Disord ; 24(1): 968, 2023 Dec 14.
Article in En | MEDLINE | ID: mdl-38098024
ABSTRACT

BACKGROUND:

Allergies against implant materials are still not fully understood. Despite controversies about its relevance, some patients need treatment with hypoallergenic implants. This study compared coated and standard total knee arthroplasty (TKA) regarding inflammatory response and patient-reported outcome measures (PROMs).

METHODS:

76 patients without self-reported allergies against implant materials were included in a RCT and received a coated or standard TKA of the same cemented posterior-stabilized knee system. 73 patients completed the 3-year follow-up. Two patients died and there was one revision surgery. Serum levels of cytokines with a possible role in implant allergy were measured in patient`s serum (IL-1beta, IL-5, IL-6, IL-8, IL-10, IFN γ, TNF α) prior to, one and three years after surgery. Furthermore, PROMs including knee function (Oxford Knee Score, Knee Society Score) and health-related quality of life (QoL, EuroQuol questionnaire) were assessed. Additionally, 8 patients with patch-test proven skin allergy against implant materials who received the coated implant were assessed similarly and compared to a matched-pair group receiving the same implant.

RESULTS:

There were no differences in function and QoL between the assessed groups at any follow-up. The majority of patients demonstrated no elevation of the measured blood cytokines. Cytokine patterns showed no differences between study groups at any follow-up. The allergy patients demonstrated slower functional improvement and minor differences in cytokine pattern. Yet these results were not significant. There were no differences in the matched-pair analysis.

CONCLUSION:

We observed no relevant increase in serum cytokine levels in any group. The inflammatory response measured seems limited, even in allergy patients. Furthermore, there were no differences between coated and standard TKA in non-allergy patients in the 3-year Follow-Up period. TRIAL REGISTRATION The study protocol was registered in the US National Institutes of Health's database ( http//www. CLINICALTRIALS gov ) registry under NCT03424174 on 03/17/2016.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Arthroplasty, Replacement, Knee / Osteoarthritis, Knee / Hypersensitivity / Knee Prosthesis Limits: Humans Language: En Journal: BMC Musculoskelet Disord Journal subject: FISIOLOGIA / ORTOPEDIA Year: 2023 Document type: Article Affiliation country: Germany

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Arthroplasty, Replacement, Knee / Osteoarthritis, Knee / Hypersensitivity / Knee Prosthesis Limits: Humans Language: En Journal: BMC Musculoskelet Disord Journal subject: FISIOLOGIA / ORTOPEDIA Year: 2023 Document type: Article Affiliation country: Germany