Your browser doesn't support javascript.
loading
Shape-memory sawtooth-arm embracing clamp used in complex femoral revision hip arthroplasty for stem stability: average 9-year follow-up study.
Hu, Yi; Xu, Zhengquan; Qiao, Hua; Kong, Keyu; Li, Huiwu; Zhang, Jingwei.
Affiliation
  • Hu Y; Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, 639# Zhizaoju Road, Shanghai, 200011, P. R. China.
  • Xu Z; Department of Orthopaedic Surgery, Suzhou Hospital, Nanjing Medical University, 16# Baita West Road, Suzhou, Jiangsu, 215000, P. R. China.
  • Qiao H; Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, 639# Zhizaoju Road, Shanghai, 200011, P. R. China.
  • Kong K; Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, 639# Zhizaoju Road, Shanghai, 200011, P. R. China.
  • Li H; Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, 639# Zhizaoju Road, Shanghai, 200011, P. R. China. huiwu1223@163.com.
  • Zhang J; Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, 639# Zhizaoju Road, Shanghai, 200011, P. R. China. zjw_ys@163.com.
BMC Musculoskelet Disord ; 24(1): 970, 2023 Dec 15.
Article in En | MEDLINE | ID: mdl-38102625
ABSTRACT

BACKGROUND:

Nickel-Titanium shape-memory sawtooth-arm embracing clamps (SSECs) have been used in revision total hip arthroplasties (rTHAs) to protect stem stability. This study was to introduce this technique and report its mid to long-term clinical and radiographic outcomes.

METHODS:

We retrospectively reviewed all patients implanted with SSECs in our department from January 2008 to December 2015. 41 patients (41 hips) were finally included. Radiographs and Harris hip scores (HHS) were collected. Radiographs were blindly analyzed for evidence of loosening, subsidence and stress shielding. HHS were compared to previous records by student's t tests. The average follow-up period was 9.3 years.

RESULTS:

All stems were stably fixed with no signs of loosening. The mean stem subsidence was 0.9 mm (range, 0 to 3 mm). Only one patient (2.4%) demonstrated the fourth degree of stress shielding, with the others none or minor bone resorption. The mean HHS at the final follow-up was 84.2 (range, 81 to 91), which was improved from 17.4 (range, 0 to 37) before surgery. No implant failures or re-revisions occurred. Dislocation occurred in 1 case during the follow-up period.

CONCLUSIONS:

The SSEC protected stem fixation and achieved favorable clinical and radiographic outcomes in this 9-year follow-up study. It offered an additional extramedullary fixation option for surgeons to choose from in treating complex femoral revision arthroplasties.