ENDOANGEL versus water exchange for the detection of colorectal adenomas.
Therap Adv Gastroenterol
; 16: 17562848231218570, 2023.
Article
in En
| MEDLINE
| ID: mdl-38116388
ABSTRACT
Background:
Recently, the ENDOANGEL (EN) system, a computer-assisted detection technique, and water exchange (WE) assisted colonoscopy have both been shown to increase the colorectal adenoma detection rate (ADR).Objectives:
The aim of this study was to compare the ADR between EN- and WE-assisted colonoscopy.Design:
This was a retrospective study.Methods:
Data from patients who underwent either EN- or WE-assisted colonoscopy between October 2021 and August 2022 were analysed consecutively. The primary outcome measure was the ADR.Results:
The ADR was found to be similar between the EN and WE groups, with 80 out of 199 (40.2%) patients in the EN group compared to 78 out of 174 (44.8%) patients in the WE group [1.21; 95% confidence interval (CI), 0.80-1.83]. In the analysis using stabilized inverse probability treatment weighting after adjustment for confounding factors, both colonoscopy methods had similar performance in terms of ADR (1.41; 95% CI, 0.88-2.27).Conclusion:
EN was found to be comparable to WE in terms of ADR during colonoscopy, and both methods may be effectively used in clinical practice.