Your browser doesn't support javascript.
loading
Intraocular pressure increase after Nd:YAG laser capsulotomy and anterior segment optical coherence tomography analysis.
Keles, Ali; Karaman, Suleyman Korhan.
Affiliation
  • Keles A; Department of Ophthalmology, Faculty of Medicine, Bilecik Seyh Edebali University, 11230, Bilecik, Turkey. alikeles06@gmail.com.
  • Karaman SK; Department of Ophthalmology, University of Health Sciences, Ulucanlar Eye Training and Research Hospital, Ankara, Turkey.
Lasers Med Sci ; 39(1): 13, 2023 Dec 22.
Article in En | MEDLINE | ID: mdl-38135858
ABSTRACT
This study is to determine whether post-procedure intraocular pressure (IOP) increase is associated with the anterior chamber angle in cases of Neodymium yttrium-aluminum garnet (Nd YAG) laser capsulotomy. The study included 51 eyes with posterior capsule opacification. Initial IOP values of the patients were compared with IOP values without intraocular pressure-lowering administration at the end of the 1st hour, 1st day, 3rd day, and 7th day after NdYAG laser capsulotomy. The anterior segment angle configuration was evaluated using anterior segment optical coherence tomography analysis without dilatation before the procedure. The anterior chamber angle (ACA) and angle opening distances of 500 and 750 µm (AOD500 and AOD750) in the nasal and temporal quadrants were examined. The mean pre-laser IOP value only increased significantly at 1st hour post-laser (13.02 ± 3.02 mmHg vs 14.16 ± 4.07 mmHg, p = 0.016). In eyes with ACA below 40° in both the nasal and temporal quadrants, mean IOP increased significantly at 1st hour post-laser (p = 0.025 and p = 0.032, respectively), while it was not significant in eyes with ACA above 40° (p > 0.05). No correlation was found between ACA, AOD500, and AOD750 values and IOP changes at the first hour (p > 0.05). Except for the first hour after NdYAG laser capsulotomy, no significant increase in IOP was observed. This elevation was higher in eyes with ACA less than 40°. In patients with a narrow ACA, first-hour follow-up may be beneficial in terms of susceptibility to increased IOP.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Glaucoma / Lasers, Solid-State / Capsule Opacification Limits: Humans Language: En Journal: Laser in medical science / Lasers Med Sci / Lasers med. sci Journal subject: BIOTECNOLOGIA / RADIOLOGIA Year: 2023 Document type: Article Affiliation country: Turkey Country of publication: United kingdom

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Glaucoma / Lasers, Solid-State / Capsule Opacification Limits: Humans Language: En Journal: Laser in medical science / Lasers Med Sci / Lasers med. sci Journal subject: BIOTECNOLOGIA / RADIOLOGIA Year: 2023 Document type: Article Affiliation country: Turkey Country of publication: United kingdom