Your browser doesn't support javascript.
loading
Research on 18th-Century Building Structures in Terms of Static Scheme Changes.
Mackiewicz, Monika; Krentowski, Janusz Ryszard; Ziminski, Kamil; Skotnicka-Siepsiak, Aldona.
Affiliation
  • Mackiewicz M; Faculty of Civil Engineering and Environmental Sciences, Bialystok University of Technology, Wiejska 45E, 15-351 Bialystok, Poland.
  • Krentowski JR; Faculty of Civil Engineering and Environmental Sciences, Bialystok University of Technology, Wiejska 45E, 15-351 Bialystok, Poland.
  • Ziminski K; Faculty of Civil Engineering and Environmental Sciences, Bialystok University of Technology, Wiejska 45E, 15-351 Bialystok, Poland.
  • Skotnicka-Siepsiak A; Faculty of Geoengineering, University of Warmia and Mazury in Olsztyn, Heweliusza 4, 10-724 Olsztyn, Poland.
Materials (Basel) ; 16(24)2023 Dec 18.
Article in En | MEDLINE | ID: mdl-38138832
ABSTRACT
The evaluation of the technical condition of historic buildings that have operated for several hundred years is a complicated issue. Even buildings that are in very poor condition must be checked and assessed in terms of their further repair, strengthening, or compliance with conditions that allow the facility to be safely operated. Most 18th-century buildings have not survived to this day retaining their original arrangements and structural elements. Renovations and repair work in the past were often carried out using materials of uncertain quality, with repair work of different qualities and without detailed analysis or methodology, based only on the experience of the former builders. In historic structures, the character of the work of individual structural elements has often changed due to significant material degradation, the poor quality of repair work, or the loss of adequate support. When load transfers change, internal forces are redistributed, and, as a result, the static scheme changes. This article presents an overview of identified defects affecting the change in static schemes in historical building structures built in the 18th century, using the example of a historic building with a large number of aforementioned defects. The process of assessing the technical condition of the facility is presented, in which non-destructive testing (NDT) methods were used. Detailed computational analyses were carried out for the wooden roof truss structure, which had partially lost its support.