Deep vein thrombosis and pulmonary embolism: a prospective, observational study to evaluate diagnostic performance of the Tina-quant D-Dimer Gen.2 assay.
Front Cardiovasc Med
; 10: 1142465, 2023.
Article
in En
| MEDLINE
| ID: mdl-38169956
ABSTRACT
Background:
D-Dimer testing is a diagnostic tool for exclusion of deep vein thrombosis (DVT) and pulmonary embolism (PE). This study evaluated the diagnostic performance of the Tina-quant® D-Dimer Gen.2 assay (Roche Diagnostics International Ltd, Rotkreuz, Switzerland) in patients with low/intermediate pre-test probability of DVT/PE using standard, age-, and clinical probability-adjusted cut-offs.Methods:
In this prospective, observational, multicenter study (July 2017-August 2019), plasma samples were collected from hospital emergency departments and specialist referral centers. DVT/PE was diagnosed under hospital standard procedures and imaging protocols. A standard D-dimer cut-off of 0.5â µg fibrinogen equivalent units (FEU)/ml was combined with the three-level Wells score; cut-offs adjusted for age (age × 0.01â µgâ FEU/ml for patients >50 years) and clinical probability (1â µgâ FEU/ml for low probability) were also evaluated. An assay comparison was conducted in a subset of samples using the Tina-quant D-Dimer Gen.2 assay and the previously established routine laboratory assay, STA-Liatest D-Di Plus assay (Stago Deutschland GmbH, Düsseldorf, Germany).Results:
2,897 patients were enrolled; 2,516 completed the study (DVT cohort 1,741 PE cohort 775). Clinical assessment plus D-dimer testing using the standard cut-off resulted in 317 (DVT) and 230 (PE) false positives, and zero (DVT) and one (PE) false negatives. Negative predictive value (NPV) was 100.0% (95% confidence interval [CI] 99.7%-100.0%) and 99.8% (95% CI 98.8%-100.0%) for DVT and PE, respectively. After age-adjustment, NPV was 99.9% (95% CI 99.6%-100.0%) and 99.1% (95% CI 97.8-99.7) for DVT and PE, respectively. False positive rates decreased (>50%) in clinical probability-adjusted analyses vs. primary analysis. In the assay comparison, the performances of the two assays were comparable.Conclusion:
The Tina-quant D-Dimer Gen.2 assay and standard D-dimer cut-off level combined with the three-level Wells score accurately identified patients with a very low probability of DVT/PE.
Full text:
1
Collection:
01-internacional
Database:
MEDLINE
Type of study:
Clinical_trials
/
Diagnostic_studies
/
Guideline
/
Observational_studies
/
Prognostic_studies
/
Risk_factors_studies
Language:
En
Journal:
Front Cardiovasc Med
Year:
2023
Document type:
Article
Affiliation country:
Germany
Country of publication: