Your browser doesn't support javascript.
loading
Artificial intelligence-based screening for amblyopia and its risk factors: comparison with four classic stereovision tests.
Csizek, Zsófia; Mikó-Baráth, Eszter; Budai, Anna; Frigyik, Andrew B; Pusztai, Ágota; Nemes, Vanda A; Závori, László; Fülöp, Diána; Czigler, András; Szabó-Guth, Kitti; Buzás, Péter; Piñero, David P; Jandó, Gábor.
Affiliation
  • Csizek Z; Institute of Physiology, Medical School, University of Pécs, Pécs, Hungary.
  • Mikó-Baráth E; Centre for Neuroscience, University of Pécs, Pécs, Hungary.
  • Budai A; Institute of Physiology, Medical School, University of Pécs, Pécs, Hungary.
  • Frigyik AB; Centre for Neuroscience, University of Pécs, Pécs, Hungary.
  • Pusztai Á; Institute of Physiology, Medical School, University of Pécs, Pécs, Hungary.
  • Nemes VA; Institute of Mathematics and Informatics, Faculty of Sciences, University of Pécs, Pécs, Hungary.
  • Závori L; Department of Ophthalmology, Medical School, University of Pécs, Pécs, Hungary.
  • Fülöp D; Institute of Physiology, Medical School, University of Pécs, Pécs, Hungary.
  • Czigler A; Centre for Neuroscience, University of Pécs, Pécs, Hungary.
  • Szabó-Guth K; Institute of Physiology, Medical School, University of Pécs, Pécs, Hungary.
  • Buzás P; Centre for Neuroscience, University of Pécs, Pécs, Hungary.
  • Piñero DP; Institute of Physiology, Medical School, University of Pécs, Pécs, Hungary.
  • Jandó G; Centre for Neuroscience, University of Pécs, Pécs, Hungary.
Front Med (Lausanne) ; 10: 1294559, 2023.
Article in En | MEDLINE | ID: mdl-38196833
ABSTRACT

Introduction:

The development of costs-effective and sensitive screening solutions to prevent amblyopia and identify its risk factors (strabismus, refractive problems or mixed) is a significant priority of pediatric ophthalmology. The main objective of our study was to compare the classification performance of various vision screening tests, including classic, stereoacuity-based tests (Lang II, TNO, Stereo Fly, and Frisby), and non-stereoacuity-based, low-density static, dynamic, and noisy anaglyphic random dot stereograms. We determined whether the combination of non-stereoacuity-based tests integrated in the simplest artificial intelligence (AI) model could be an alternative method for vision screening.

Methods:

Our study, conducted in Spain and Hungary, is a non-experimental, cross-sectional diagnostic test assessment focused on pediatric eye conditions. Using convenience sampling, we enrolled 423 children aged 3.6-14 years, diagnosed with amblyopia, strabismus, or refractive errors, and compared them to age-matched emmetropic controls. Comprehensive pediatric ophthalmologic examinations ascertained diagnoses. Participants used filter glasses for stereovision tests and red-green goggles for an AI-based test over their prescribed glasses. Sensitivity, specificity, and the area under the ROC curve (AUC) were our metrics, with sensitivity being the primary endpoint. AUCs were analyzed using DeLong's method, and binary classifications (pathologic vs. normal) were evaluated using McNemar's matched pair and Fisher's nonparametric tests.

Results:

Four non-overlapping groups were studied (1) amblyopia (n = 46), (2) amblyogenic (n = 55), (3) non-amblyogenic (n = 128), and (4) emmetropic (n = 194), and a fifth group that was a combination of the amblyopia and amblyogenic groups. Based on AUCs, the AI combination of non-stereoacuity-based tests showed significantly better performance 0.908, 95% CI (0.829-0.958) for detecting amblyopia and its risk factors than most classical tests Lang II 0.704, (0.648-0.755), Stereo Fly 0.780, (0.714-0.837), Frisby 0.754 (0.688-0.812), p < 0.02, n = 91, DeLong's method). At the optimum ROC point, McNemar's test indicated significantly higher sensitivity in accord with AUCs. Moreover, the AI solution had significantly higher sensitivity than TNO (p = 0.046, N = 134, Fisher's test), as well, while the specificity did not differ.

Discussion:

The combination of multiple tests utilizing anaglyphic random dot stereograms with varying parameters (density, noise, dynamism) in AI leads to the most advanced and sensitive screening test for identifying amblyopia and amblyogenic conditions compared to all the other tests studied.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Type of study: Diagnostic_studies / Etiology_studies / Prognostic_studies / Risk_factors_studies / Screening_studies Language: En Journal: Front Med (Lausanne) Year: 2023 Document type: Article Affiliation country: Hungary

Full text: 1 Collection: 01-internacional Database: MEDLINE Type of study: Diagnostic_studies / Etiology_studies / Prognostic_studies / Risk_factors_studies / Screening_studies Language: En Journal: Front Med (Lausanne) Year: 2023 Document type: Article Affiliation country: Hungary