Your browser doesn't support javascript.
loading
CHART: a novel system for detector evaluation against toxic chemical aerosols.
Durán Jiménez, Dinesh; Venema, Tom; de Bruin-Hoegée, Mirjam; Alkema, Duurt P W; Busker, Ruud W; van Wuijckhuijse, Arjan L.
Affiliation
  • Durán Jiménez D; Department of CBRN Protection, TNO Defence, Safety and Security, Lange Kleiweg 137, 2288GJ, Rijswijk, The Netherlands. Dinesh.duranjimenez@tno.nl.
  • Venema T; Department of CBRN Protection, TNO Defence, Safety and Security, Lange Kleiweg 137, 2288GJ, Rijswijk, The Netherlands.
  • de Bruin-Hoegée M; Department of CBRN Protection, TNO Defence, Safety and Security, Lange Kleiweg 137, 2288GJ, Rijswijk, The Netherlands.
  • Alkema DPW; van 't Hoff Institute for Molecular Sciences, Faculty of Science, University of Amsterdam, P.O. Box 94157, 1090GD, Amsterdam, The Netherlands.
  • Busker RW; Department of CBRN Protection, TNO Defence, Safety and Security, Lange Kleiweg 137, 2288GJ, Rijswijk, The Netherlands.
  • van Wuijckhuijse AL; Department of CBRN Protection, TNO Defence, Safety and Security, Lange Kleiweg 137, 2288GJ, Rijswijk, The Netherlands.
Sci Rep ; 14(1): 1050, 2024 Jan 10.
Article in En | MEDLINE | ID: mdl-38200048
ABSTRACT
Concern over the possibility of deliberate dispersion of chemical warfare agents and highly toxic pharmaceutical based agents as persistent aerosols has raised the need for experimental assessment of current and future defensive capabilities of armed forces and law enforcement agencies. Therefor we herewith present the design, realization and validation of the Chemical Hot Aerosol Research Tool (CHART) as a validated and safe experimental set-up for performance evaluation of chemical detection and identification equipment against chemical warfare agents and other highly toxic compounds. In the CHART liquid and solid compounds in solution or suspension are being dispersed as aerosols in a nebulization chamber. A broad dynamic particle size range can be generated, including particles known to be able to reach the lower respiratory tract. The aerosol generated is presented to the detection system-under-test while being monitored and characterized in real-time, using an optical particle counter and a time-of-flight aerosol analyzer, respectively. Additionally, the chemical composition of the aerosol is ex situ measured by analytical chemical methods. Evidently, in the design of the CHART significant emphasis was placed on laboratory safety and containment of toxic chemicals. The CHART presented in this paper has proven to be an indispensable experimental tool to study detectors and fieldable identification equipment against toxic chemical aerosols.

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Sci Rep Year: 2024 Document type: Article Affiliation country: Netherlands Country of publication: United kingdom