Your browser doesn't support javascript.
loading
Assessment of Cardiorespiratory and Metabolic Contributions in an Extreme Intensity CrossFit® Benchmark Workout.
Rios, Manoel; Becker, Klaus Magno; Cardoso, Filipa; Pyne, David B; Reis, Victor Machado; Moreira-Gonçalves, Daniel; Fernandes, Ricardo J.
Affiliation
  • Rios M; Center of Research, Education Innovation and Intervention in Sport and Porto Biomechanics Laboratory, Faculty of Sport, University of Porto, 4200-450 Porto, Portugal.
  • Becker KM; Center of Research, Education Innovation and Intervention in Sport and Porto Biomechanics Laboratory, Faculty of Sport, University of Porto, 4200-450 Porto, Portugal.
  • Cardoso F; Center of Research, Education Innovation and Intervention in Sport and Porto Biomechanics Laboratory, Faculty of Sport, University of Porto, 4200-450 Porto, Portugal.
  • Pyne DB; Research Institute for Sport & Exercise, University of Canberra, Canberra 2617, Australia.
  • Reis VM; Department of Sport Sciences, Exercise and Health, University of Trás-os-Montes e Alto Douro, 5001-801 Vila Real, Portugal.
  • Moreira-Gonçalves D; Research Center in Sports Sciences, Health Sciences and Human Development, 5001-801 Vila Real, Portugal.
  • Fernandes RJ; Research Center in Physical Activity, Health and Leisure, Faculty of Sport, University of Porto, 4200-450 Porto, Portugal.
Sensors (Basel) ; 24(2)2024 Jan 14.
Article in En | MEDLINE | ID: mdl-38257605
ABSTRACT
Our purpose was to characterize the oxygen uptake kinetics (VO2), energy systems contributions and total energy expenditure during a CrossFit® benchmark workout performed in the extreme intensity domain. Fourteen highly trained male CrossFitters, aged 28.3 ± 5.4 years, with height 177.8 ± 9.4 cm, body mass 87.9 ± 10.5 kg and 5.6 ± 1.8 years of training experience, performed the Isabel workout at maximal exertion. Cardiorespiratory variables were measured at baseline, during exercise and the recovery period, with blood lactate and glucose concentrations, including the ratings of perceived exertion, measured pre- and post-workout. The Isabel workout was 117 ± 10 s in duration and the VO2 peak was 47.2 ± 4.7 mL·kg-1·min-1, the primary component amplitude was 42.0 ± 6.0 mL·kg-1·min-1, the time delay was 4.3 ± 2.2 s and the time constant was 14.2 ± 6.0 s. The accumulated VO2 (0.6 ± 0.1 vs. 4.8 ± 1.0 L·min-1) value post-workout increased substantially when compared to baseline. Oxidative phosphorylation (40%), glycolytic (45%) and phosphagen (15%) pathways contributed to the 245 ± 25 kJ total energy expenditure. Despite the short ~2 min duration of the Isabel workout, the oxygen-dependent and oxygen-independent metabolism energy contributions to the total metabolic energy release were similar. The CrossFit® Isabel requires maximal effort and the pattern of physiological demands identifies this as a highly intensive and effective workout for developing fitness and conditioning for sports.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Benchmarking / Energy Metabolism Type of study: Prognostic_studies Limits: Humans / Male Language: En Journal: Sensors (Basel) Year: 2024 Document type: Article Affiliation country: Portugal

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Benchmarking / Energy Metabolism Type of study: Prognostic_studies Limits: Humans / Male Language: En Journal: Sensors (Basel) Year: 2024 Document type: Article Affiliation country: Portugal