Ensure the accuracy and consistency of biochemical analyzer test results: Chemometrics for instrument and inter-instrument item comparison in Chinese hospital laboratory.
Song, Xue-Dong; Li, Shou-Xia; Qin, Zhi-Mei; Chen, Ding-Li; Guo, Li-Li; Liu, Cai-Ru; Yang, Xiao; Peng, Ke-Nan; Dai, Er-Hei.
Affiliation
  • Song XD; Department of Laboratory Medicine, Handan Central Hospital, Hebei Medical University, Handan, Hebei, 056001, China.
  • Li SX; Department of Laboratory Medicine, Handan Central Hospital, Hebei Medical University, Handan, Hebei, 056001, China.
  • Qin ZM; Department of Laboratory Medicine, Handan Central Hospital, Hebei Medical University, Handan, Hebei, 056001, China.
  • Chen DL; Department of Laboratory Medicine, Handan Central Hospital, Hebei Medical University, Handan, Hebei, 056001, China.
  • Guo LL; Department of Laboratory Medicine, Handan Central Hospital, Hebei Medical University, Handan, Hebei, 056001, China.
  • Liu CR; Department of Laboratory Medicine, Handan Central Hospital, Hebei Medical University, Handan, Hebei, 056001, China.
  • Yang X; Department of Laboratory Medicine, Handan Central Hospital, Hebei Medical University, Handan, Hebei, 056001, China.
  • Peng KN; Department of Laboratory Medicine, Hebei General Hospital, Hebei Medical University, Shijiazhuang, Hebei, 050051, China.
  • Dai EH; Department of Laboratory Medicine, The Fifth Hospital of Shijiazhuang, Hebei Medical University, Shijiazhuang, Hebei, 050024, China.
Heliyon ; 10(1): e24306, 2024 Jan 15.
Article in En | MEDLINE | ID: mdl-38268603
ABSTRACT
Biochemical analyzers are vital instruments that utilize the principle of photoelectric colorimetry to quantify a specific chemical composition in body fluids. This analysis provides critical data for the diagnosis, treatment, prognosis, and overall health status of various diseases in clinical practice. However, the performance of a biochemical analyzer can vary significantly between different brands or over time within the same brand. Therefore, it is imperative to regularly assess the performance of the analyzer to ensure consistent results for longitudinal studies and to maintain day-to-day data consistency. Additionally, when multiple analyzers are utilized, it is necessary to evaluate the performance of each instrument to ensure accurate results across multiple platforms. In this study, we developed and verified an experimental evaluation scheme for the analytical performance of the instrument, chemometrics for biochemical analyzers, utilizing national reference materials and patient sera as the experimental subjects. We evaluated the performance of the optical system, temperature control system, sample-adding system, and detection system to confirm the feasibility of this scheme. We also compared the analytical performance of different brands of biochemical analyzers for routine biochemical tests, such as liver function, kidney function, ion, blood lipids, blood glucose, and myocardial enzyme spectrum. Using the AU 5400 as a control and the ADVIA 2400 as the comparison system, the relative variation in inter-instrument comparison data was found to be acceptable at the clinical medicine decision level. In conclusion, the performance of a biochemical analyzer can vary significantly between different brands or over time within the same brand. Regular evaluations are necessary to ensure accurate and consistent results across different analyzers. This study provides a feasible scheme for evaluating the analytical performance of biochemical analyzers that can be used to ensure the accuracy and consistency of the results of different brands of automatic chemical analyzers in the laboratory.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Type of study: Observational_studies / Prognostic_studies Aspects: Patient_preference Language: En Journal: Heliyon Year: 2024 Document type: Article Affiliation country: China Country of publication: United kingdom