Your browser doesn't support javascript.
loading
Innovations in Aortic Valve Replacement: A Comprehensive Overview of the Intuity Rapid Deployment Valve.
Alaklabi, Abdulaziz M; Abdul Rab, Saleha; Sabbah, Belal N; Maklad, Ahmed Essam; Dokollari, Aleksander; Van den Eynde, Jef; Pompeu Sa, Michel; Arjomandi Rad, Arian; Ahsan, Muhammad Rauf; Fatehi Hassanabad, Ali.
Affiliation
  • Alaklabi AM; From the College of Medicine, Alfaisal University, Riyadh, Saudi Arabia.
  • Abdul Rab S; From the College of Medicine, Alfaisal University, Riyadh, Saudi Arabia.
  • Sabbah BN; From the College of Medicine, Alfaisal University, Riyadh, Saudi Arabia.
  • Maklad AE; From the College of Medicine, Alfaisal University, Riyadh, Saudi Arabia.
  • Dokollari A; Section of Cardiac Surgery, St. Boniface Hospital, University of Manitoba, Winnipeg, Manitoba, Canada.
  • Van den Eynde J; Department of Cardiovascular Sciences, KU Leuven, Leuven, Belgium.
  • Pompeu Sa M; Department of Cardiothoracic Surgery, University of Pittsburgh, Pittsburgh, PA.
  • Arjomandi Rad A; UPMC Heart and Vascular Institute, Pittsburgh, PA.
  • Ahsan MR; Medical Sciences Division, University of Oxford, Oxford, UK; and.
  • Fatehi Hassanabad A; Section of Cardiac Surgery, Department of Cardiac Sciences, Libin Cardiovascular Institute, University of Calgary, Calgary, Canada.
Cardiol Rev ; 2024 Feb 09.
Article in En | MEDLINE | ID: mdl-38334371
ABSTRACT
Rapid deployment/sutureless (RDS) valves have recently emerged as an innovative surgical solution, providing an alternative to traditional methods of surgical aortic valve replacement (SAVR) by eliminating the need for suture placement and tying. This innovation leads to a reduction in aortic crossclamp and cardiopulmonary bypass times, enhancing the efficiency of the procedure. Among the 2 available RDS valves, the Edwards Intuity valve in particular has been demonstrated to be a particularly promising substitute in the field of SAVR. The Intuity valve distinguishes itself from other RDS and conventional valves by yielding superior outcomes, such as a significant reduction in mortality, increase in the longevity of the valve, and a marked decrease in both mean and peak transvalvular pressure gradients. These benefits collectively contribute to its appeal as a favorable new solution. However, further investigation is needed to conclusively determine the long-term outcomes and safety of RDS valves. Nevertheless, the utilization of the Intuity valve presents an exciting solution to the existing limitations of conventional and minimally invasive SAVR, especially for patients afflicted with severe aortic stenosis.

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Cardiol Rev Journal subject: ANGIOLOGIA / CARDIOLOGIA Year: 2024 Document type: Article Affiliation country: Saudi Arabia

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Cardiol Rev Journal subject: ANGIOLOGIA / CARDIOLOGIA Year: 2024 Document type: Article Affiliation country: Saudi Arabia