Your browser doesn't support javascript.
loading
[Alignment method for metabolite chromatographic peaks using an N-acyl glycine retention index system].
Hao, Jun-di; Chen, Yao-Yu; Wang, Yan-Zhen; An, Na; Bai, Pei-Rong; Zhu, Quan-Fei; Feng, Yu-Qi.
Affiliation
  • Hao JD; College of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072, China.
  • Chen YY; College of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072, China.
  • Wang YZ; College of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072, China.
  • An N; College of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072, China.
  • Bai PR; College of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072, China.
  • Zhu QF; School of Public Health, Wuhan University, Wuhan 430071, China.
  • Feng YQ; College of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072, China.
Se Pu ; 42(2): 159-163, 2024 Feb.
Article in Zh | MEDLINE | ID: mdl-38374596
ABSTRACT
Peak alignment is a crucial data-processing step in untargeted metabolomics analysis that aims to integrate metabolite data from multiple liquid chromatography-mass spectrometry (LC-MS) batches for enhanced comparability and reliability. However, slight variations in the chromatographic separation conditions can result in retention time (RT) shifts between consecutive analyses, adversely affecting peak alignment accuracy. In this study, we present a retention index (RI)-based chromatographic peak-shift correction (CPSC) strategy to address RT shifts and align chromatographic peaks for metabolomics studies. A series of N-acyl glycine homologues (C2-C23) was synthesized as calibrants, and an LC RI system was established. This system effectively corrected RT shifts arising from variations in flow rate, gradient elution, instrument systems, and chromatographic columns. Leveraging the RI system, we successfully adjusted the RT of raw data to mitigate RT shifts and then implemented the Joint Aligner algorithm for peak alignment. We assessed the accuracy of the RI-based CPSC strategy using pooled human fecal samples as a test model. Notably, the application of the RI-based CPSC strategy to a long-term dataset spanning 157 d as an illustration revealed a significant enhancement in peak alignment accuracy from 15.5% to 80.9%, indicating its ability to substantially improve peak-alignment precision in multibatch LC-MS analyses.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Algorithms / Metabolomics Limits: Humans Language: Zh Journal: Se Pu Year: 2024 Document type: Article Affiliation country: China

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Algorithms / Metabolomics Limits: Humans Language: Zh Journal: Se Pu Year: 2024 Document type: Article Affiliation country: China