Your browser doesn't support javascript.
loading
Multi-Echo Complex Quantitative Susceptibility Mapping and Quantitative Blood Oxygen Level-Dependent Magnitude (mcQSM + qBOLD or mcQQ) for Oxygen Extraction Fraction (OEF) Mapping.
Cho, Junghun; Zhang, Jinwei; Spincemaille, Pascal; Zhang, Hang; Nguyen, Thanh D; Zhang, Shun; Gupta, Ajay; Wang, Yi.
Affiliation
  • Cho J; Department of Biomedical Engineering, State University of New York at Buffalo, Buffalo, NY 14228, USA.
  • Zhang J; Department of Radiology, Weill Cornell Medicine, New York, NY 10065, USA.
  • Spincemaille P; Department of Radiology, Weill Cornell Medicine, New York, NY 10065, USA.
  • Zhang H; Department of Radiology, Weill Cornell Medicine, New York, NY 10065, USA.
  • Nguyen TD; Department of Radiology, Weill Cornell Medicine, New York, NY 10065, USA.
  • Zhang S; Department of Radiology, Weill Cornell Medicine, New York, NY 10065, USA.
  • Gupta A; Department of Radiology, Weill Cornell Medicine, New York, NY 10065, USA.
  • Wang Y; Department of Radiology, Weill Cornell Medicine, New York, NY 10065, USA.
Bioengineering (Basel) ; 11(2)2024 Jan 29.
Article in En | MEDLINE | ID: mdl-38391617
ABSTRACT
Oxygen extraction fraction (OEF), the fraction of oxygen that tissue extracts from blood, is an essential biomarker used to directly assess tissue viability and function in neurologic disorders. In ischemic stroke, for example, increased OEF can indicate the presence of penumbra-tissue with low perfusion yet intact cellular integrity-making it a primary therapeutic target. However, practical OEF mapping methods are not currently available in clinical settings, owing to the impractical data acquisitions in positron emission tomography (PET) and the limitations of existing MRI techniques. Recently, a novel MRI-based OEF mapping technique, termed QQ, was proposed. It shows high potential for clinical use by utilizing a routine sequence and removing the need for impractical multiple gas inhalations. However, QQ relies on the assumptions of Gaussian noise in susceptibility and multi-echo gradient echo (mGRE) magnitude signals for OEF estimation. This assumption is unreliable in low signal-to-noise ratio (SNR) regions like disease-related lesions, risking inaccurate OEF estimation and potentially impacting clinical decisions. Addressing this, our study presents a novel multi-echo complex QQ (mcQQ) that models realistic Gaussian noise in mGRE complex signals. We implemented mcQQ using a deep learning framework (mcQQ-NET) and compared it with the existing QQ-NET in simulations, ischemic stroke patients, and healthy subjects, using identical training and testing datasets and schemes. In simulations, mcQQ-NET provided more accurate OEF than QQ-NET. In the subacute stroke patients, mcQQ-NET showed a lower average OEF ratio in lesions relative to unaffected contralateral normal tissue than QQ-NET. In the healthy subjects, mcQQ-NET provided uniform OEF maps, similar to QQ-NET, but without unrealistically high OEF outliers in areas of low SNR, such as SNR ≤ 15 (dB). Therefore, mcQQ-NET improves OEF accuracy by more accurately reflecting realistic Gaussian noise in complex mGRE signals. Its enhanced sensitivity to OEF abnormalities, based on more realistic biophysics modeling, suggests that mcQQ-NET has potential for investigating tissue variability in neurologic disorders.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Bioengineering (Basel) Year: 2024 Document type: Article Affiliation country: United States Publication country: CH / SUIZA / SUÍÇA / SWITZERLAND

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Bioengineering (Basel) Year: 2024 Document type: Article Affiliation country: United States Publication country: CH / SUIZA / SUÍÇA / SWITZERLAND