Glucose values from the same continuous glucose monitoring sensor significantly differ among readers with different generations of algorithm.
Babaya, Naru; Noso, Shinsuke; Hiromine, Yoshihisa; Taketomo, Yasunori; Niwano, Fumimaru; Yoshida, Sawa; Yasutake, Sara; Kawabata, Yumiko; Maeda, Norikazu; Ikegami, Hiroshi.
Affiliation
  • Babaya N; Department of Endocrinology, Metabolism and Diabetes, Faculty of Medicine, Kindai University, 377-2 Ohno-higashi, Osaka-sayama, Osaka, 589-8511, Japan. babaya@med.kindai.ac.jp.
  • Noso S; Department of Endocrinology, Metabolism and Diabetes, Faculty of Medicine, Kindai University, 377-2 Ohno-higashi, Osaka-sayama, Osaka, 589-8511, Japan.
  • Hiromine Y; Department of Endocrinology, Metabolism and Diabetes, Faculty of Medicine, Kindai University, 377-2 Ohno-higashi, Osaka-sayama, Osaka, 589-8511, Japan.
  • Taketomo Y; Department of Endocrinology, Metabolism and Diabetes, Faculty of Medicine, Kindai University, 377-2 Ohno-higashi, Osaka-sayama, Osaka, 589-8511, Japan.
  • Niwano F; Department of Endocrinology, Metabolism and Diabetes, Faculty of Medicine, Kindai University, 377-2 Ohno-higashi, Osaka-sayama, Osaka, 589-8511, Japan.
  • Yoshida S; Department of Endocrinology, Metabolism and Diabetes, Faculty of Medicine, Kindai University, 377-2 Ohno-higashi, Osaka-sayama, Osaka, 589-8511, Japan.
  • Yasutake S; Department of Endocrinology, Metabolism and Diabetes, Faculty of Medicine, Kindai University, 377-2 Ohno-higashi, Osaka-sayama, Osaka, 589-8511, Japan.
  • Kawabata Y; Department of Endocrinology, Metabolism and Diabetes, Faculty of Medicine, Kindai University, 377-2 Ohno-higashi, Osaka-sayama, Osaka, 589-8511, Japan.
  • Maeda N; Department of Endocrinology, Metabolism and Diabetes, Faculty of Medicine, Kindai University, 377-2 Ohno-higashi, Osaka-sayama, Osaka, 589-8511, Japan.
  • Ikegami H; Department of Endocrinology, Metabolism and Diabetes, Faculty of Medicine, Kindai University, 377-2 Ohno-higashi, Osaka-sayama, Osaka, 589-8511, Japan.
Sci Rep ; 14(1): 5099, 2024 03 01.
Article in En | MEDLINE | ID: mdl-38429333
ABSTRACT
Continuous glucose monitoring (CGM) values obtained from CGM systems using the same sensor but with different internal algorithms (the first- and third-generation FreeStyle Libre (1st-gen-libre and 3rd-gen-libre, respectively)) were compared. We used 19,819 paired and simultaneously measured CGM values of 13 patients with diabetes. The average CGM value was significantly higher (P < 0.0001) and the time below range (CGM value < 70 mg/dL) was significantly lower (P < 0.0001) with the 3rd-gen-libre than with the 1st-gen-libre. There was a significant correlation (P < 0.0001) between the CGM values of the 3rd-gen-libre (y-axis, mg/dL) and 1st-gen-libre (x-axis, mg/dL) using the following formula y = 0.9728x + 10.024. On assessing the association between glycated hemoglobin (HbA1c (%), y-axis) and the average CGM values (x-axis, mg/dL) by applying the obtained equation to previously reported 1st-gen-libre data and converting it to 3rd-gen-libre data, we obtained the equation y = 0.02628x + 3.233, indicating that the glucose management indicator reported in the West may be underestimated compared with the laboratory-measured HbA1c in the Japanese population. Glucose values from the same sensor were found to be significantly different between readers with different algorithms, and the calculation of CGM-related indices may need to be individualized for each device.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Blood Glucose / Diabetes Mellitus, Type 1 Limits: Humans Language: En Journal: Sci Rep Year: 2024 Document type: Article Affiliation country: Japan

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Blood Glucose / Diabetes Mellitus, Type 1 Limits: Humans Language: En Journal: Sci Rep Year: 2024 Document type: Article Affiliation country: Japan