Your browser doesn't support javascript.
loading
A potential novel technique for measurement of pulp volume on periapical radiography: A pilot study.
Satir, Samed; Özel, Selale; Orhan, Kaan.
Affiliation
  • Satir S; Department of Oral and Maxillofacial Radiology, Faculty of Dentistry, Karamanoglu Mehmetbey University, Karaman, Turkey.
  • Özel S; Department of Oral and Maxillofacial Radiology, Faculty of Dentistry, Altinbas University, Istanbul, Turkey.
  • Orhan K; Department of Dentomaxillofacial Radiology, Faculty of Dentistry, Ankara University, Ankara, Turkey.
Kaohsiung J Med Sci ; 40(5): 499-505, 2024 May.
Article in En | MEDLINE | ID: mdl-38446557
ABSTRACT
Pulp volume can be assessed during dental treatment. Three-dimensional imaging techniques are not routinely used for this purpose because of high radiation doses. This study aimed to develop a novel method to measure pulp volume using periapical radiography. In this study, cone-beam computed tomography (CBCT) was used as a reference method. Periapical radiography and CBCTs obtained from the same patients (n = 32) were recorded. Pulp volume was determined by observing the density differences between the pulp and peripheral structures using ImageJ. A method of graph and volume calculation was developed for each tooth. The Shapiro-Wilk test and Mann-Whitney U test were used to show normality and non-normal distributions. The Bland-Altman plot was used to show the scattering of the mean versus difference values of the measurements of the two methods used to calculate the pulp volume. Normality was evaluated using the Shapiro-Wilk test. CBCT measurements are normally distributed (p = 0.307), while ImageJ is not normally distributed (p = 0.027). Therefore, the mean difference between the two groups was analyzed using the nonparametric Mann-Whitney U test. There was a statistically significant difference between the CBCT and ImageJ measurements (p = 0.01). According to Spearman's correlation analysis, the results obtained from the novel method were moderately correlated with those obtained from the reference method (r = 0.444). The results of this study indicated that a novel method-based Java software can be used to calculate pulp volume using low-dose radiation containing periapical radiography.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Dental Pulp / Cone-Beam Computed Tomography Limits: Adult / Female / Humans / Male / Middle aged Language: En Journal: Kaohsiung J Med Sci Journal subject: MEDICINA Year: 2024 Document type: Article Affiliation country: Turkey Country of publication:

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Dental Pulp / Cone-Beam Computed Tomography Limits: Adult / Female / Humans / Male / Middle aged Language: En Journal: Kaohsiung J Med Sci Journal subject: MEDICINA Year: 2024 Document type: Article Affiliation country: Turkey Country of publication: