Development and Validation of a New High-Performance Liquid Chromatography-Ultraviolet Assay for Quantification of Mitoxantrone in Plasma of BALB/c-nu Mice.
J Chromatogr Sci
; 2024 Mar 15.
Article
in En
| MEDLINE
| ID: mdl-38493310
ABSTRACT
The concentration of mitoxantrone in the blood of mice was determined by a high-performance liquid chromatography-ultraviolet method with aloe-emodin as the internal standard. The separation was performed on a Hypersil BDS2 column (4.6 × 250 mm, 5 µm) as the analytical column, the mobile Phase A was acetonitrile, and B was 20-mM potassium dihydrogen phosphate (adding 1% triethylamine and adjusting the pH to 2.8 with phosphoric acid) and 4.6-mM sodium octyl sulfonate. The flow rate was 1.0 mL·min-1, the detection wavelength was 243 nm, the column temperature is 25 ± 5°C and the injection amount was 20 µL. Finally, the linear range of mitoxantrone was 5-200 µg·mL-1, and the correlation coefficient was r = 0.9999. The recovery rate of the method was 91.93-105.5%, and the extraction recovery rate was 91.45-105.5%. The intraday precision and interday precision were <3.29% (limit of detection = 0.3 µg·mL-1). The HPLC method established in this paper was simple, rapid, sensitive and accurate, and can be used to determine the content of mitoxantrone in mouse plasma after tail vein injection.
Full text:
1
Collection:
01-internacional
Database:
MEDLINE
Language:
En
Journal:
J Chromatogr Sci
Year:
2024
Document type:
Article
Affiliation country:
China
Country of publication:
United States