Your browser doesn't support javascript.
loading
Electrostatic Repulsion Hydrophilic Interaction Liquid Chromatography (ERLIC) for the Quantitative Analysis of Polyamines.
Dörfel, Dominik; Rohn, Sascha; Jantzen, Eckard.
Affiliation
  • Dörfel D; GALAB Laboratories GmbH, Am Schleusengraben 7, 21029 Hamburg, Germany; Department of Food Chemistry and Analysis, Institute of Food Technology and Food Chemistry, Technische Universität Berlin, Gustav Meyer Allee 25, 13355 Berlin, Germany. Electronic address: dominik.doerfel@galab.de.
  • Rohn S; Department of Food Chemistry and Analysis, Institute of Food Technology and Food Chemistry, Technische Universität Berlin, Gustav Meyer Allee 25, 13355 Berlin, Germany.
  • Jantzen E; GALAB Laboratories GmbH, Am Schleusengraben 7, 21029 Hamburg, Germany.
J Chromatogr A ; 1720: 464820, 2024 Apr 12.
Article in En | MEDLINE | ID: mdl-38507872
ABSTRACT
Highly polar low molecular weight organic molecules are still very challenging to analyze by liquid chromatography. Yet, with the steadily increasing application of metabolomics and similar approaches in chemical analysis, separating polar compounds might be even more important. However, almost all established liquid chromatography techniques (i.e., normal and reversed phase, hydrophilic interaction liquid chromatography (HILIC), ion chromatography) struggle with either carry-over, low sensitivity, or a lack of retention. For improving these shortcomings, electrostatic repulsion hydrophilic interaction chromatography (ERLIC) might be an alternative. By combining a HILIC mobile phase, that is highly organic with a low water content, and an ion exchange column, a distinct layer system develops. When the analyte's charge is of the same direction as the stationary phase, retention and elution are determined by two antagonistic forces electrostatic repulsion and hydrophilicity. One prominent group of challenging polar analytes are the polyamines cadaverine, putrescine, spermidine, and spermine. Carrying charges from +2 to +4 at physiological pH, these compounds are essential cell constituents and found in all living organisms. However, they are still notoriously challenging to analyze via the established liquid chromatography methods. In the present work, an ERLIC tandem mass spectrometry method has been exemplarily developed, optimized, and validated for the quantitative determination of cadaverine, putrescine, spermidine, and spermine. This method enables symmetrical peak shapes and good separation of analytes with different charges while simultaneously selectively detecting the co-eluting diamines by MS/MS. Furthermore, high linearity (R > 0.998) and sensitivity (LODs ≤ 2 ng/mL) have been proven. Thus, ERLIC may be interesting for both targeted and untargeted analysis approaches of highly charged low molecular weight organic molecules.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Polyamines / Tandem Mass Spectrometry Language: En Journal: J Chromatogr A Year: 2024 Document type: Article