Your browser doesn't support javascript.
loading
Endovascular repair of ascending aortic pathologies in patients unfit for open surgery: case series and literature review.
Ferraresi, Marco; Katsarou, Maria; Luigi Molinari, Alessandro Carlo; Segreti, Sara; Rossi, Giovanni.
Affiliation
  • Ferraresi M; Division of Vascular Surgery, Cardio-Thoracic-Vascular Department, Alessandro Manzoni Hospital, Lecco, Italy.
  • Katsarou M; Division of Vascular Surgery, Cardio-Thoracic-Vascular Department, Alessandro Manzoni Hospital, Lecco, Italy.
  • Luigi Molinari AC; Division of Vascular Surgery, Cardio-Thoracic-Vascular Department, Alessandro Manzoni Hospital, Lecco, Italy.
  • Segreti S; Division of Vascular Surgery, Cardio-Thoracic-Vascular Department, Alessandro Manzoni Hospital, Lecco, Italy.
  • Rossi G; Division of Vascular Surgery, Cardio-Thoracic-Vascular Department, Alessandro Manzoni Hospital, Lecco, Italy.
J Vasc Surg Cases Innov Tech ; 10(3): 101455, 2024 Jun.
Article in En | MEDLINE | ID: mdl-38510094
ABSTRACT
The number of vascular centers performing endovascular repair of ascending aortic disease is constantly increasing. Accordingly to the guidelines, open surgical repair remains the gold standard for these pathologies. However, approximately one quarter of patients are deemed unfit for open surgery. In this study, we describe three cases of ascending thoracic endovascular aortic repair (TEVAR) performed at our center. All the patients were deemed unfit for open surgery by the aortic team. Two patients had an ascending aortic pseudoaneurysm, and the third had a focal type A aortic dissection. In two cases, we used two abdominal aortic cuffs deployed from zone 0B to zone 0C, with no need for supra-aortic trunk debranching. In one case, we performed a "reverse" extrathoracic debranching, and we deployed a thoracic endograft from zone 0B to zone 2. Complications included one minor stroke and one inguinal hematoma. In one patient with an infected pseudoaneurysm, we performed ascending TEVAR as a bridge strategy for open repair. This patient developed a type Ia endoleak; however, clinical stabilization and infection control were obtained, and he was able to undergo heart surgery successfully. He underwent a second reintervention to treat superior mesenteric embolic occlusion. At 2 years of follow-up, all three patients were alive. Our preliminary experience demonstrates the technical feasibility and clinical appropriateness of ascending TEVAR using standard, commercially available endografts. However, no consensus has been reached regarding some critical aspects, such as the development of a standardized technique or the efficacy of the currently available devices. The improvements in graft design and the adoption of the "aortic team" approach could help in the near future to standardize the procedure, establish appropriate indications, and ensure good clinical outcomes.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: J Vasc Surg Cases Innov Tech Year: 2024 Document type: Article Affiliation country: Italy

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: J Vasc Surg Cases Innov Tech Year: 2024 Document type: Article Affiliation country: Italy
...