Your browser doesn't support javascript.
loading
A deep-learning model for intracranial aneurysm detection on CT angiography images in China: a stepwise, multicentre, early-stage clinical validation study.
Hu, Bin; Shi, Zhao; Lu, Li; Miao, Zhongchang; Wang, Hao; Zhou, Zhen; Zhang, Fandong; Wang, Rongpin; Luo, Xiao; Xu, Feng; Li, Sheng; Fang, Xiangming; Wang, Xiaodong; Yan, Ge; Lv, Fajin; Zhang, Meng; Sun, Qiu; Cui, Guangbin; Liu, Yubao; Zhang, Shu; Pan, Chengwei; Hou, Zhibo; Liang, Huiying; Pan, Yuning; Chen, Xiaoxia; Li, Xiaorong; Zhou, Fei; Schoepf, U Joseph; Varga-Szemes, Akos; Garrison Moore, W; Yu, Yizhou; Hu, Chunfeng; Zhang, Long Jiang.
Affiliation
  • Hu B; Department of Radiology, Jinling Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, China.
  • Shi Z; Department of Radiology, Jinling Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, China.
  • Lu L; Department of Radiology, the Affiliated Hospital of Xuzhou Medical University, Xuzhou, Jiangsu, China.
  • Miao Z; Department of Medical Imaging, the First People's Hospital of Lianyungang, Lianyungang, Jiangsu, China.
  • Wang H; Deepwise Artificial Intelligence (AI) Lab, Deepwise, Beijing, China.
  • Zhou Z; Deepwise Artificial Intelligence (AI) Lab, Deepwise, Beijing, China.
  • Zhang F; Deepwise Artificial Intelligence (AI) Lab, Deepwise, Beijing, China.
  • Wang R; Department of Medical Imaging, Guizhou Province People's Hospital, Guiyang, Guizhou, China.
  • Luo X; Department of Radiology, Ma'anshan People's Hospital, Ma'anshan, Anhui, China.
  • Xu F; Department of Medical Imaging, the Affiliated Suqian First People's Hospital of Nanjing Medical University, Suqian, Jiangsu, China.
  • Li S; Department of Radiology, People's Hospital, Hubei University of Medicine, Shiyan, Hubei, China.
  • Fang X; Department of Medical Imaging, the Affiliated Wuxi People's Hospital of Nanjing Medical University, Wuxi, Jiangsu, China.
  • Wang X; Department of Radiology, General Hospital of Ningxia Medical University, Yinchuan, Ningxia, China.
  • Yan G; Department of Medical Imaging, the First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi, China.
  • Lv F; Department of Radiology, the First Affiliated Hospital of Chongqing Medical University, Chongqing, China.
  • Zhang M; Department of Radiology, People's Hospital of Sanya, Sanya, Hainan, China.
  • Sun Q; Department of Radiology, Lanzhou University Second Hospital, Lanzhou, Gansu, China.
  • Cui G; Department of Radiology, Tangdu Hospital, Air Force Medical University (Fourth Military Medical University), Xi'an, Shaanxi, China.
  • Liu Y; Medical Imaging Center, Shenzhen Hospital of Southern Medical University, Shenzhen, Guangdong, China.
  • Zhang S; Deepwise Artificial Intelligence (AI) Lab, Deepwise, Beijing, China.
  • Pan C; Institute of Artificial Intelligence, Beihang University, Beijing, China.
  • Hou Z; Department of Radiology, Medical Imaging Center, Peking University Shougang Hospital, Beijing, China.
  • Liang H; Medical Big Data Center, Guangdong Provincial People's Hospital, Guangzhou Guangdong, China.
  • Pan Y; Department of Radiology, Ningbo First Hospital, Ningbo, Zhejiang, China.
  • Chen X; Department of Radiology, Third Center Medical Center, Chinese PLA General Hospital, Beijing, China.
  • Li X; Department of Radiology, General Hospital of Southern Theater Command, PLA, Guangzhou, Guangdong, China.
  • Zhou F; Department of Radiology, Central Hospital of Jilin City, Jilin, China.
  • Schoepf UJ; Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC, USA.
  • Varga-Szemes A; Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC, USA.
  • Garrison Moore W; Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC, USA.
  • Yu Y; Department of Computer Science, The University of Hong Kong, Hong Kong Special Administrative Region, China.
  • Hu C; Department of Radiology, the Affiliated Hospital of Xuzhou Medical University, Xuzhou, Jiangsu, China.
  • Zhang LJ; Department of Radiology, Jinling Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, China. Electronic address: kevinzhlj@nju.edu.cn.
Lancet Digit Health ; 6(4): e261-e271, 2024 Apr.
Article in En | MEDLINE | ID: mdl-38519154
ABSTRACT

BACKGROUND:

Artificial intelligence (AI) models in real-world implementation are scarce. Our study aimed to develop a CT angiography (CTA)-based AI model for intracranial aneurysm detection, assess how it helps clinicians improve diagnostic performance, and validate its application in real-world clinical implementation.

METHODS:

We developed a deep-learning model using 16 546 head and neck CTA examination images from 14 517 patients at eight Chinese hospitals. Using an adapted, stepwise implementation and evaluation, 120 certified clinicians from 15 geographically different hospitals were recruited. Initially, the AI model was externally validated with images of 900 digital subtraction angiography-verified CTA cases (examinations) and compared with the performance of 24 clinicians who each viewed 300 of these cases (stage 1). Next, as a further external validation a multi-reader multi-case study enrolled 48 clinicians to individually review 298 digital subtraction angiography-verified CTA cases (stage 2). The clinicians reviewed each CTA examination twice (ie, with and without the AI model), separated by a 4-week washout period. Then, a randomised open-label comparison study enrolled 48 clinicians to assess the acceptance and performance of this AI model (stage 3). Finally, the model was prospectively deployed and validated in 1562 real-world clinical CTA cases.

FINDINGS:

The AI model in the internal dataset achieved a patient-level diagnostic sensitivity of 0·957 (95% CI 0·939-0·971) and a higher patient-level diagnostic sensitivity than clinicians (0·943 [0·921-0·961] vs 0·658 [0·644-0·672]; p<0·0001) in the external dataset. In the multi-reader multi-case study, the AI-assisted strategy improved clinicians' diagnostic performance both on a per-patient basis (the area under the receiver operating characteristic curves [AUCs]; 0·795 [0·761-0·830] without AI vs 0·878 [0·850-0·906] with AI; p<0·0001) and a per-aneurysm basis (the area under the weighted alternative free-response receiver operating characteristic curves; 0·765 [0·732-0·799] vs 0·865 [0·839-0·891]; p<0·0001). Reading time decreased with the aid of the AI model (87·5 s vs 82·7 s, p<0·0001). In the randomised open-label comparison study, clinicians in the AI-assisted group had a high acceptance of the AI model (92·6% adoption rate), and a higher AUC when compared with the control group (0·858 [95% CI 0·850-0·866] vs 0·789 [0·780-0·799]; p<0·0001). In the prospective study, the AI model had a 0·51% (8/1570) error rate due to poor-quality CTA images and recognition failure. The model had a high negative predictive value of 0·998 (0·994-1·000) and significantly improved the diagnostic performance of clinicians; AUC improved from 0·787 (95% CI 0·766-0·808) to 0·909 (0·894-0·923; p<0·0001) and patient-level sensitivity improved from 0·590 (0·511-0·666) to 0·825 (0·759-0·880; p<0·0001).

INTERPRETATION:

This AI model demonstrated strong clinical potential for intracranial aneurysm detection with improved clinician diagnostic performance, high acceptance, and practical implementation in real-world clinical cases.

FUNDING:

National Natural Science Foundation of China. TRANSLATION For the Chinese translation of the abstract see Supplementary Materials section.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Intracranial Aneurysm / Deep Learning Limits: Humans Language: En Journal: Lancet Digit Health Year: 2024 Document type: Article Affiliation country: China

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Intracranial Aneurysm / Deep Learning Limits: Humans Language: En Journal: Lancet Digit Health Year: 2024 Document type: Article Affiliation country: China
...