Your browser doesn't support javascript.
loading
Biceps brachii elastography in well-trained men post eccentric exercise-induced muscle damage.
Brandão, Maria Clara Albuquerque; Matias, Lino de Azevedo; da Matta, Thiago Torres; de Oliveira, Liliam Fernandes.
Affiliation
  • Brandão MCA; Laboratório de Biomecânica Muscular, Universidade Federal do Rio de Janeiro, Avenida Horácio de Macedo, 2030, Centro de Tecnologia, Bloco I, Subsolo 044C, Rio de Janeiro, RJ, 21949-900, Brazil. mclara@peb.ufrj.br.
  • Matias LA; Laboratório de Biomecânica Muscular, Universidade Federal do Rio de Janeiro, Avenida Horácio de Macedo, 2030, Centro de Tecnologia, Bloco I, Subsolo 044C, Rio de Janeiro, RJ, 21949-900, Brazil.
  • da Matta TT; Laboratório de Biomecânica Muscular, Universidade Federal do Rio de Janeiro, Avenida Horácio de Macedo, 2030, Centro de Tecnologia, Bloco I, Subsolo 044C, Rio de Janeiro, RJ, 21949-900, Brazil.
  • de Oliveira LF; Laboratório de Biomecânica Muscular, Universidade Federal do Rio de Janeiro, Avenida Horácio de Macedo, 2030, Centro de Tecnologia, Bloco I, Subsolo 044C, Rio de Janeiro, RJ, 21949-900, Brazil.
J Ultrasound ; 2024 Mar 28.
Article in En | MEDLINE | ID: mdl-38546928
ABSTRACT

PURPOSE:

Recent advancements in elastography techniques, specifically supersonic shearwave elastography (SWE), have enabled non-invasive assessment of muscle stiffness. However, there is limited research on the immediate and short-term effects of eccentric exercise-induced muscle damage (EIMD) in well-trained individuals. This study aimed to follow up on the effects of eccentric training on the biceps brachialis stiffness by supersonic shearwave imaging (SSI) as well as the soreness and elbow flexion maximal voluntary isometric contraction (MVIC), immediately post-intervention, at 10 min, 48 h, and 96 h in well-trained men.

METHODS:

Thirteen well-trained males participated in the study. Baseline measurements of elastography images, MVIC of the elbow flexors, and muscle soreness were obtained. The participants performed an eccentric exercise protocol (4 sets X 10 repetitions) on the dynamometer isokinetic and elastography measurements were repeated immediately post-exercise, at 10 min, 48 h, and 96 h.

RESULTS:

Significant reductions in stiffness (measured by shear modulus (µ)) were observed immediately and at 10 min post-exercise. MVIC exhibited significant reductions immediately after, 10 min, and 48 h compared to baseline measurements. Muscle soreness peaked at 48 h, persisting until 96 h.

CONCLUSIONS:

The BB stiffness and MVIC reduction immediately post-eccentric exercise in well-trained men, suggest the potential involvement of mechanical stress and sarcomere rupture. Trained individuals may exhibit a distinct response to EIMD compared to untrained individuals, highlighting the applicability of elastography in monitoring acute biomechanical changes following high-intensity exercise.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: J Ultrasound Year: 2024 Document type: Article Affiliation country: Brazil

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: J Ultrasound Year: 2024 Document type: Article Affiliation country: Brazil