3.0T magnetic resonance imaging-based hip bone models for femoroacetabular impingement syndrome are equivalent to computed tomography-based models.
Newhouse, Alexander C; Alter, Thomas D; Handoklow, Lyla A; Espinoza Orías, Alejandro A; Inoue, Nozomu; Nho, Shane J.
Affiliation
  • Newhouse AC; Department of Orthopedic Surgery, Rush University Medical Center, Chicago, Illinois, USA.
  • Alter TD; Department of Orthopedic Surgery, Rush University Medical Center, Chicago, Illinois, USA.
  • Handoklow LA; Department of Orthopedic Surgery, Rush University Medical Center, Chicago, Illinois, USA.
  • Espinoza Orías AA; Department of Bioengineering, University of Illinois Chicago, Chicago, Illinois, USA.
  • Inoue N; Department of Orthopedic Surgery, Rush University Medical Center, Chicago, Illinois, USA.
  • Nho SJ; Department of Orthopedic Surgery, Rush University Medical Center, Chicago, Illinois, USA.
J Orthop Res ; 42(9): 2017-2025, 2024 Sep.
Article in En | MEDLINE | ID: mdl-38564320
ABSTRACT
This study aimed to compare three-dimensional (3D) proximal femoral and acetabular surface models generated from 3.0T magnetic resonance imaging (MRI) to the clinical gold standard of computed tomography (CT). Ten intact fresh-frozen cadaveric hips underwent CT and 3.0T MRI scans. The CT- and MRI-based segmented models were superimposed using a validated 3D-3D registration volume-merge method to compare them. The least surface-to-surface distance between the models was calculated by a point-to-surface calculation algorithm using a custom-written program. The variables of interest were the signed and absolute surface-to-surface distance between the paired bone models. One-sample t-tests were performed using a signed and absolute test value of 0.16 mm and 0.37 mm, respectively, based on a previous study that validated 1.5T MRI bone models by comparison with CT bone models. For the femur, the average signed and absolute surface-to-surface distance was 0.18 ± 0.09 mm and 0.30 ± 0.06 mm, respectively. There was no difference in the signed surface-to-surface distance and the 0.16 mm test value (t = 0.650, p = 0.532). However, the absolute surface-to-surface difference was less than the 0.37 mm test value (t = -4.025, p = 0.003). For the acetabulum, the average signed and absolute surface-to-surface distance was -0.06 ± 0.06 mm and 0.26 ± 0.04 mm, respectively. The signed (t = -12.569, p < 0.001) and absolute (t = -8.688, p < 0.001) surface-to-surface difference were less than the 0.16 mm and 0.37 mm test values, respectively. Our data shows that 3.0T MRI bone models are more similar to CT bone models than previously validated 1.5T MRI bone models. This is likely due to the higher resolution of the 3T data.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Magnetic Resonance Imaging / Tomography, X-Ray Computed / Femoracetabular Impingement Limits: Adult / Aged / Female / Humans / Male / Middle aged Language: En Journal: J Orthop Res Year: 2024 Document type: Article Affiliation country: United States

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Magnetic Resonance Imaging / Tomography, X-Ray Computed / Femoracetabular Impingement Limits: Adult / Aged / Female / Humans / Male / Middle aged Language: En Journal: J Orthop Res Year: 2024 Document type: Article Affiliation country: United States