Your browser doesn't support javascript.
loading
Effect of bioceramic powder abrasion on different implant surfaces.
Abuhajar, Eman; Salim, Nesreen A; Satterthwaite, Julian D; Silikas, Nick; Anweigi, Lamyia M.
Affiliation
  • Abuhajar E; Faculty of Medicine, Dentistry and Oral Surgery, University of Tripoli, Tripoli, Libya.
  • Salim NA; Prosthodontic Department, School of Dentistry, The University of Jordan, Consultant in Fixed and Removable Prosthodontics, The University of Jordan Hospital, Amman, Jordan.
  • Satterthwaite JD; Division of Dentistry, School of Medical Sciences, The University of Manchester, Manchester, UK.
  • Silikas N; School of Dentistry, The University of Manchester, Manchester, UK.
  • Anweigi LM; College of Dental Medicine, QU Health, Qatar University, Doha, Qatar.
J Prosthodont ; 2024 Apr 09.
Article in En | MEDLINE | ID: mdl-38594924
ABSTRACT

PURPOSE:

Bioceramic coatings have been shown to promote bone repair, which aids in the early integration of implants. This study aimed to evaluate the influence of air abrasion with a bioceramic abrasive on the surface characteristics of different implant materials and surfaces. The dissolution of the applied treatment from the surfaces over 3 weeks was also assessed. MATERIALS AND

METHODS:

Discs of three alloys used for dental implants were studied and compared two types of commercially pure titanium (CpTi)/ (CpTi SLActive) and titanium-zirconia (TiZr). The tested surfaces were CpTi control (CpC), sandblasted (SB), sandblasted and acid-etched (SBE), and CpTi SLActive®, (TiZr) Roxolid®. Three discs from each group underwent air abrasion with apatite bioceramic powders, 95% hydroxyapatite (HA)/5% calcium oxide (CaO), and 90% hydroxyapatite (HA)/10% calcium oxide (CaO). The treated discs were surface characterized by optical profilometry to obtain surface roughness, scanning electron microscopy (SEM), and energy dispersive X-ray spectroscopy (EDS) to compare element weight percentages of titanium, calcium, and phosphate. Dissolution was assessed using inductively coupled plasma optic emission spectrometry (ICP-OES).

RESULTS:

Bioceramic powders were deposited on all tested surfaces leading to changes in surface characteristics. The only statistically significant differences between the material groups for surface roughness were found with 95% HA/5% CaO powder in the Sp and Rp parameters (p = 0.03 and 0.04, respectively). There were no significant differences in the Ca and P wt% between all groups and powders 95% HA/5% CaO and 90% HA/10% CaO (p = 0.14, 0.18, and p = 0.15, 0.12, respectively). A non-uniform dispersion of the treatment on the surface layer was visible on all treated surfaces. The bioceramic powder continued to dissolute from the tested surfaces for 3 weeks.

CONCLUSION:

Bioceramic abrasion modifies implant surface characteristics, although the change in surface characteristics resulting from such treatment was not influenced by the implant material or surface treatment. Air abrasion with hydroxyapatite and calcium oxide bioceramics leaves powder deposits on the treated implant surfaces that could potentially influence the healing of implants affected by peri-implantitis.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: J Prosthodont Journal subject: ODONTOLOGIA Year: 2024 Document type: Article Affiliation country: Libya

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: J Prosthodont Journal subject: ODONTOLOGIA Year: 2024 Document type: Article Affiliation country: Libya