Your browser doesn't support javascript.
loading
The Effects of Ozone Sterilization on the Chemical and Mechanical Properties of 3D-Printed Biocompatible PMMA.
Morosavljevic, Ivan; Kozak, Drazan; Kosor, Tihomir; Morosavljevic, Janko; Ferlic, Luka; Gubeljak, Nenad.
Affiliation
  • Morosavljevic I; Mechanical Engineering Faculty in Slavonski Brod, University of Slavonski Brod, 35000 Slavonski Brod, Croatia.
  • Kozak D; Mechanical Engineering Faculty in Slavonski Brod, University of Slavonski Brod, 35000 Slavonski Brod, Croatia.
  • Kosor T; Faculty of Chemistry and Technology, University of Split, 21000 Split, Croatia.
  • Morosavljevic J; Mechanical Engineering Faculty in Slavonski Brod, University of Slavonski Brod, 35000 Slavonski Brod, Croatia.
  • Ferlic L; Faculty of Mechanical Engineering, University of Maribor, 2000 Maribor, Slovenia.
  • Gubeljak N; Faculty of Mechanical Engineering, University of Maribor, 2000 Maribor, Slovenia.
Micromachines (Basel) ; 15(4)2024 Mar 29.
Article in En | MEDLINE | ID: mdl-38675283
ABSTRACT
Since ozone is highly corrosive, it can substantially affect the mechanical and chemical properties of the materials; consequently, it could affect the applicability of those materials in medical applications. The effect of ozone sterilization on the chemical and mechanical properties of additively manufactured specimens of biocompatible poly(methyl-methacrylate) was observed. FDM 3D-printed specimens of biocompatible PMMA in groups of five were exposed to high concentrations of ozone generated by corona discharge for different durations and at different ozone concentrations inside an enclosed chamber with embedded and calibrated ozone, temperature, and humidity sensors. A novel approach using laser-induced fluorescence (LIF) and spark-discharge optical emission spectrometry (SD-OES) was used to determine an eventual change in the chemical composition of specimens. Mechanical properties were determined by testing the tensile strength and Young's modulus. A calibrated digital microscope was used to observe the eventual degradation of material on the surface of the specimens. SD-OES and LIF analysis results do not show any detectable sterilization-caused chemical degradation, and no substantial difference in mechanical properties was detected. There was no detectable surface degradation observed under the digital microscope. The results obtained suggest that ozone sterilization appears to be a suitable technique for sterilizing PMMA medical devices.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Micromachines (Basel) Year: 2024 Document type: Article Affiliation country: Croatia

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Micromachines (Basel) Year: 2024 Document type: Article Affiliation country: Croatia