Your browser doesn't support javascript.
loading
Development and Validation of Novel HPLC Methods for Quantitative Determination of Vitamin D3 in Tablet Dosage Form.
Gohar, Muhammad Saqib; Rahman, Taj Ur; Bahadur, Ali; Ali, Ashraf; Alharthi, Sarah; Al-Shaalan, Nora Hamad.
Affiliation
  • Gohar MS; Department of Chemistry, Mohi-Ud-Din Islamic University, Nerian Sharif, Azad Jammu & Kashmir 12080, Pakistan.
  • Rahman TU; Department of Chemistry, Mohi-Ud-Din Islamic University, Nerian Sharif, Azad Jammu & Kashmir 12080, Pakistan.
  • Bahadur A; Department of Chemistry, School of Natural Sciences (SNS), National University of Science and Technology (NUST), H-12, Islamabad 46000, Pakistan.
  • Ali A; School of Chemistry & Chemical Engineering, Henan University of Technology, Zhengzhou 450001, China.
  • Alharthi S; Department of Chemistry, College of Science, Taif University, P.O. Box 11099, Taif 21944, Saudi Arabia.
  • Al-Shaalan NH; Research Center of Basic Sciences, Engineering and High Altitude, Taif University, P.O. Box 11099, Taif 21944, Saudi Arabia.
Pharmaceuticals (Basel) ; 17(4)2024 Apr 15.
Article in En | MEDLINE | ID: mdl-38675464
ABSTRACT
In the present work, an efficient isocratic HPLC method was developed for the precise and accurate estimation of vitamin D3 in tablet form. The chromatographic conditions comprised an L3 silica column (5 µm in particle size, 4.6 mm × 250 mm) with a mobile phase n-hexane/ethyl acetate (8515 v/v) with a flow rate of 2.0 mL/min and a detection wavelength of 292 nm. The new methodology was validated for accuracy, precision, specificity, robustness, and quantification limits according to an official monograph of USP/BP and ICH guidelines. The peak areas of the six replicates of the homogeneous sample were recorded. The mean value obtained was 67,301, and the relative standard deviation (RSD) was 0.1741. The linearity and range were in the acceptable bounds, i.e., 0.999, which was calculated using regression line analysis. The results show that the method is truly acceptable as the RSD, as the flow rate was 0.81%, while for the mobile phase composition, it was 0.72%, which lies in the acceptable range. The limit of detection (LOD) and the limit of quantification (LOQ) values were 0.0539 µg/mL and 0.1633 µg/mL, respectively. The % RSD of the intra and inter-day precision of the method was deemed acceptable according to the international commission for harmonization guidelines. The developed method has potential to be used for the detection and quantification of vitamin D3 during routine analysis for tablets in dosage form.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Pharmaceuticals (Basel) Year: 2024 Document type: Article Affiliation country: Pakistan

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Pharmaceuticals (Basel) Year: 2024 Document type: Article Affiliation country: Pakistan