Your browser doesn't support javascript.
loading
Validating the Baveno Elastography Criteria of Advanced Liver Fibrosis in Two-Dimensional Shear Wave Elastography: A Prospective Pathology-Based Study.
Chen, Chia-Chang; Huang, Yao-Kuang; Wang, Ren-Ching; Fu, Jing-Tong; Lee, Shou-Wu; Tsai, Hsin-Ju; Yang, Sheng-Shun; Lee, Teng-Yu.
Affiliation
  • Chen CC; Division of Gastroenterology and Hepatology, Department of Internal Medicine, Taichung Veterans General Hospital, Taichung, Taiwan.
  • Huang YK; Department of Post-Baccalaureate Medicine, College of Medicine, National Chung Hsing University, Taichung, Taiwan.
  • Wang RC; Division of Gastroenterology and Hepatology, Department of Internal Medicine, Nantou Hospital, Ministry of Health and Welfare, Nantou, Taiwan.
  • Fu JT; Department of Pathology, China Medical University Hospital, Taichung, Taiwan.
  • Lee SW; Department of Nursing, College of Nursing, Hung Kuang University, Taichung, Taiwan.
  • Tsai HJ; Department of Pathology and Laboratory Medicine, Taichung Veterans General Hospital, Taichung, Taiwan.
  • Yang SS; Division of Gastroenterology and Hepatology, Department of Internal Medicine, Taichung Veterans General Hospital, Taichung, Taiwan.
  • Lee TY; Department of Post-Baccalaureate Medicine, College of Medicine, National Chung Hsing University, Taichung, Taiwan.
Dig Dis ; : 1-9, 2024 May 02.
Article in En | MEDLINE | ID: mdl-38697048
ABSTRACT

INTRODUCTION:

The Baveno criteria for assessing advanced liver fibrosis were mainly determined by transient elastography (TE), and its pathology-based validation studies in two-dimensional shear wave elastography (2D-SWE) remain limited. We aimed to validate the Baveno criteria through use of 2D-SWE.

METHOD:

Consecutive patients who underwent liver biopsies for various benign liver diseases were prospectively recruited. Liver stiffness measurement (LSM) was simultaneously evaluated by TE and 2D-SWE. The optimal cutoff value to predict advanced liver fibrosis was determined by the Youden Index, and the diagnostic performance was estimated using area under the receiver operating characteristic (AUROC) analysis.

RESULTS:

A total of 101 patients were enrolled having a median age of 55.0 (IQR 46.0-63.5) years, with 53 (52.48%) of them being male. Using <9 and >14 kPa as the optimal dual cutoffs, the AUROC values in TE and 2D-SWE were 0.92 (95% CI 0.83-0.97) and 0.93 (95% CI 0.84-0.98), respectively (p = 0.61). The sensitivity and specificity of LSM by TE/2D-SWE achieved rates of 94.44%/94.44% and 86.00%/88.00%, respectively. However, using the Baveno criteria, the AUROC values in TE and 2D-SWE could remain achieving 0.91 (95% CI 0.82-0.97) and 0.93 (95% CI 0.84-0.98), respectively (p = 0.36). The sensitivity and specificity in TE/2D-SWE were 88.24%/88.24% and 86.79%/90.57%, respectively.

CONCLUSION:

This study establishes the compatibility of the Baveno dual cutoff criteria with 2D-SWE, positioning it as an easily used criteria in clinical practice and research.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Dig Dis Journal subject: GASTROENTEROLOGIA Year: 2024 Document type: Article Affiliation country: Taiwan

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Dig Dis Journal subject: GASTROENTEROLOGIA Year: 2024 Document type: Article Affiliation country: Taiwan
...