Mishra, Navya; Sinha, Nitesh; Kharwar, Ramesh K; Prakash, Jay.
Affiliation
  • Mishra N; Anesthesiology, Rajendra Institute of Medical Sciences (RIMS), Ranchi, IND.
  • Sinha N; Anesthesiology, Rajendra Institute of Medical Sciences (RIMS), Ranchi, IND.
  • Kharwar RK; Anesthesiology, Rajendra Institute of Medical Sciences (RIMS), Ranchi, IND.
  • Prakash J; Anesthesiology and Critical Care, Rajendra Institute of Medical Sciences (RIMS), Ranchi, IND.
Cureus ; 16(4): e58629, 2024 Apr.
Article in En | MEDLINE | ID: mdl-38770453
ABSTRACT
Background and aim A novel supraglottic airway device of the second generation is the Ambu® Aura-i™. It is designed to accommodate standard cuffed tracheal tubes and is phthalate-free and compatible with MRI. The primary objectives of the research were to examine the properties and efficiency of Ambu® Aura-i™ as a means of enabling fiberoptic-guided intubation, the view of the glottis during fiber optic examination, the duration of intubation in fiber optic bronchoscopy, the ease of intubation, the success rate of intubation, and the duration for device removal from the tracheal tube. Methodology A hospital-based descriptive observational study was conducted with 80 patients. An adequately sized Ambu® Aura-i™ was placed after general anesthesia was induced. Following a fiberoptic examination of the view of the glottis through the Ambu® Aura-i™, the trachea was intubated under fiberoptic guidance. The Ambu® Aura-i™ insertion time, glottic view grading, ease of intubation, and time required for fiberoptic-guided intubation were recorded. Also, the time taken to remove the Ambu® Aura-i™ was documented. Results Similar levels of ease were experienced by both groups after inserting the Ambu® Aura-i™, being easy in both group 1 (37/40) and in group 2 (38/40). In group 1, the average time taken to insert the Ambu® Aura-i™ was 13.53±1.91 seconds, while in group 2, it was 13.98±2.4 seconds. The average time required for fiberoptic-guided intubation was found to be 14.95±1.85 seconds in group 1 and 14.15±1.37 seconds in group 2, indicating a statistically negligible variation. Conclusion The low cost of Ambu® Aura-i™, size suitability and availability for almost all age groups, compatibility with MRI machines, and availability in phthalate-free versions contribute to it being a more appealing and useful ventilatory device, as well as an intubation tool for both normal and emergency airway management.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Cureus Year: 2024 Document type: Article Country of publication: United States

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Cureus Year: 2024 Document type: Article Country of publication: United States