Your browser doesn't support javascript.
loading
A Novel Positive-Contrast Magnetic Resonance Imaging Line Marker for High-Dose-Rate (HDR) MRI-Assisted Radiosurgery (MARS).
Wang, Li; Ding, Yao; Bruno, Teresa L; Stafford, R Jason; Lin, Eric; Bathala, Tharakeswara K; Sanders, Jeremiah W; Ning, Matthew S; Ma, Jingfei; Klopp, Ann H; Venkatesan, Aradhana; Wang, Jihong; Martirosyan, Karen S; Frank, Steven J.
Affiliation
  • Wang L; Department of Experimental Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA.
  • Ding Y; Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA.
  • Bruno TL; Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA.
  • Stafford RJ; Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA.
  • Lin E; Department of Experimental Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA.
  • Bathala TK; Department of Diagnostic Radiology, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA.
  • Sanders JW; Department of Radiology, Mayo Clinic, Phoenix, AZ 85054, USA.
  • Ning MS; Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA.
  • Ma J; Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA.
  • Klopp AH; Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA.
  • Venkatesan A; Department of Diagnostic Radiology, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA.
  • Wang J; Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA.
  • Martirosyan KS; Department of Physics, The University of Texas Rio Grande Valley, Brownsville, TX 78500, USA.
  • Frank SJ; Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA.
Cancers (Basel) ; 16(10)2024 May 18.
Article in En | MEDLINE | ID: mdl-38792000
ABSTRACT
Magnetic resonance imaging (MRI) can facilitate accurate organ delineation and optimal dose distributions in high-dose-rate (HDR) MRI-Assisted Radiosurgery (MARS). Its use for this purpose has been limited by the lack of positive-contrast MRI markers that can clearly delineate the lumen of the HDR applicator and precisely show the path of the HDR source on T1- and T2-weighted MRI sequences. We investigated a novel MRI positive-contrast HDR brachytherapy or interventional radiotherapy line marker, C4S, consisting of C4 (visible on T1-weighted images) complexed with saline. Longitudinal relaxation time (T1) and transverse relaxation time (T2) for C4S were measured on a 1.5 T MRI scanner. High-density polyethylene (HDPE) tubing filled with C4S as an HDR brachytherapy line marker was tested for visibility on T1- and T2-weighted MRI sequences in a tissue-equivalent female ultrasound training pelvis phantom. Relaxivity measurements indicated that C4S solution had good T1-weighted contrast (relative to oil [fat] signal intensity) and good T2-weighted contrast (relative to water signal intensity) at both room temperature (relaxivity ratio > 1; r2/r1 = 1.43) and body temperature (relaxivity ratio > 1; r2/r1 = 1.38). These measurements were verified by the positive visualization of the C4S (C4/saline 5050) HDPE tube HDR brachytherapy line marker on both T1- and T2-weighted MRI sequences. Orientation did not affect the relaxivity of the C4S contrast solution. C4S encapsulated in HDPE tubing can be visualized as a positive line marker on both T1- and T2-weighted MRI sequences. MRI-guided HDR planning may be possible with these novel line markers for HDR MARS for several types of cancer.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Cancers (Basel) Year: 2024 Document type: Article Affiliation country: United States

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Cancers (Basel) Year: 2024 Document type: Article Affiliation country: United States