Instantaneous frequency measurement system based on quantum dash mode-locked laser.
Opt Express ; 32(9): 16027-16039, 2024 Apr 22.
Article in En | MEDLINE | ID: mdl-38859240
ABSTRACT
We present the theory and experimental results of a microwave photonic (MWP) filter based instantaneous frequency measurement system. A quantum dash mode-locked laser is used as an optical frequency comb source. With up to 41 flat comb lines and a real-time feedback loop for comb shaping, a set of MWP filters with linear frequency responses for either linear unit or dB unit are experimentally demonstrated. The maximum measurement frequency can be up to 20 GHz limited by the available test-and-measurement instruments. By using one MWP filter, the root-mean-square error is 51∼66 MHz, which can be improved to 42.2 MHz for linear unit, and 30.7 MHz for dB unit by using two MWP filters together.

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Opt Express / Opt. express / Optics express Journal subject: OFTALMOLOGIA Year: 2024 Document type: Article Country of publication: United States