Your browser doesn't support javascript.
loading
Frequency-Selective, Multi-Channel, Self-Powered Artificial Basilar Membrane Sensor with a Spiral Shape and 24 Critical Bands Inspired by the Human Cochlea.
Jeon, Eun-Seok; Lee, Useung; Yoon, Seongho; Hur, Shin; Choi, Hongsoo; Han, Chang-Soo.
Affiliation
  • Jeon ES; Department of Mechanical Engineering, Korea University, 145 Anam-Ro, Seongbuk-Gu, Seoul, 02841, Republic of Korea.
  • Lee U; Department of Mechanical Engineering, Korea University, 145 Anam-Ro, Seongbuk-Gu, Seoul, 02841, Republic of Korea.
  • Yoon S; Department of Mechanical Engineering, Korea University, 145 Anam-Ro, Seongbuk-Gu, Seoul, 02841, Republic of Korea.
  • Hur S; Department of Bionic Machinery, Korea Institute of Machinery and Materials (KIMM), 156 Gajeongbuk-ro, Yuseong-gu, Daejeon, 304-343, Republic of Korea.
  • Choi H; Department of Robotics and Mechatronics Engineering, DGIST-ETH Microrobot Research Center, Daegu-Gyeongbuk Institute of Science and Technology (DGIST), 333, Techno jungang-daero, Hyeonpung-Myeon, Dalseong-Gun, Daegu, 711-873, Republic of Korea.
  • Han CS; Department of Mechanical Engineering, Korea University, 145 Anam-Ro, Seongbuk-Gu, Seoul, 02841, Republic of Korea.
Adv Sci (Weinh) ; : e2400955, 2024 Jun 17.
Article in En | MEDLINE | ID: mdl-38885422
ABSTRACT
A spiral-artificial basilar membrane (S-ABM) sensor is reported that mimics the basilar membrane (BM) of the human cochlea and can detect sound by separating it into 24 sensing channels based on the frequency band. For this, an analytical function is proposed to design the width of the BM so that the frequency bands are linearly located along the length of the BM. To fabricate the S-ABM sensor, a spiral-shaped polyimide film is used as a vibrating membrane, with maximum displacement at locations corresponding to specific frequency bands of sound, and attach piezoelectric sensor modules made of poly(vinylidene fluoride-trifluoroethylene) film on top of the polyimide film to measure the vibration amplitude at each channel location. As the result, the S-ABM sensor implements a characteristic frequency band of 96-12,821 Hz and 24-independent critical bands. Using real-time signals from discriminate channels, it is demonstrated that the sensor can rapidly identify the operational noises from equipment processes as well as vehicle sounds from environmental noises on the road. The sensor can be used in a variety of applications, including speech recognition, dangerous situation recognition, hearing aids, and cochlear implants, and more.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Adv Sci (Weinh) Year: 2024 Document type: Article

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Adv Sci (Weinh) Year: 2024 Document type: Article