Your browser doesn't support javascript.
loading
Molecularly imprinted polymer-based electrochemical sensors for monitoring the persistent organic pollutants chlorophenols.
Kamel, Ayman H; Abd-Rabboh, Hisham S M; Hefnawy, A.
Affiliation
  • Kamel AH; Department, College of Science, University of Bahrain Sakhir 32038 Kingdom of Bahrain.
  • Abd-Rabboh HSM; Department of Chemistry, Faculty of Science, Ain Shams University Cairo 11566 Egypt ahkamel76@sci.asu.edu.eg ahmohamed@uob.edu.bh.
  • Hefnawy A; Chemistry Department, College of Science, King Khalid University PO Box 9004 Abha 62223 Saudi Arabia.
RSC Adv ; 14(28): 20163-20181, 2024 Jun 18.
Article in En | MEDLINE | ID: mdl-38915326
ABSTRACT
Because of the serious risks they pose to the environment and public health, chlorophenols (CPs), a typical class of the most persistent organic pollutants, have drawn increasing attention. Monitoring CPs effectively has become a pressing and difficult problem. The rapidly increasing need for onsite and real-time CP detection has led to the consideration of electrochemical sensing as a workable solution. Molecularly imprinted polymer (MIP)-based electrochemical sensing has emerged as a promising area for environmental monitoring in response to this analytical problem. MIPs, in conjunction with miniature electrochemical transducers, provide the opportunity to detect target analytes in situ. These devices have the advantages of great chemical and physical stability, cheap production costs, good selectivity, and quick response times. Most studies suggest that these sensors use nanoparticles to improve their analytical properties, especially sensitivity. Furthermore, these sensors have successfully used real water samples without the need for time-consuming pretreatment procedures. This article provides an overview of electrochemical MIP-based sensors reported to detect CPs in water samples. To obtain the highest sensitivity, special consideration is given to the fabrication of the sensors, which includes the use of various functional monomers, sensing platforms, and materials. Several other parameters are also discussed, including the linear concentration range, limit of detection, and the types of water samples that were examined.

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: RSC Adv Year: 2024 Document type: Article Country of publication: United kingdom

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: RSC Adv Year: 2024 Document type: Article Country of publication: United kingdom