Your browser doesn't support javascript.
loading
Investigation on the contaminate of hand washing activities on the surface of environmental objects in intensive care unit.
Tian, Fang-Ying; Wang, Xue-Yu; Meng, Hao-Peng; Kang, Jian-Bang; Zhao, Ming; Wang, Hong-Wei.
Affiliation
  • Tian FY; Department of Nosocomial Infection Management, The Second Hospital of Shanxi Medical University, Taiyuan, 030001, Shanxi, China. tfy8048@163.com.
  • Wang XY; Department of Nosocomial Infection Management, The Second Hospital of Shanxi Medical University, Taiyuan, 030001, Shanxi, China. 1411665136@qq.com.
  • Meng HP; School of Geology and Environment, Xi'an University of Science and Technology, Xi'an, 710054, Shaanxi, China.
  • Kang JB; Department of Pharmacy, The Second Hospital of Shanxi Medical University, Taiyuan, 030001, Shanxi, China.
  • Zhao M; Nursing College of Shanxi Medical University, Taiyuan, 030001, Shanxi, China.
  • Wang HW; Nursing College of Shanxi Medical University, Taiyuan, 030001, Shanxi, China.
Sci Rep ; 14(1): 15431, 2024 07 04.
Article in En | MEDLINE | ID: mdl-38965239
ABSTRACT
To detect the contaminate of faucets in hospitals and the splash during hand washing, and to explore the reasonable layout of hand washing pools. Two faucets with roughly the same spatial layout in the ICU of a third-class first-class general hospital were selected, and the farthest splashing distance and specific splashing points were measured by color paper. Samples were detected by ATP detection technology and routine microbial detection method, and the contaminate of faucets was analyzed. After 72 h of daily hand-washing activities, the furthest distance to the splash point was about 100 cm around the faucet, and the place 40-110 cm around the faucet was contaminated seriously. The farthest distance that the splash point reached was about 80 cm around the faucet with the center of the circle, and the area 40-60 cm around the faucet was heavily contaminated. The distance from the water outlet of the long handle and the short handle faucet to the detection point had a high negative correlation (r = - 0.811, P < 0.001) and a moderate negative correlation (r = - 0.475, P = 0.001) with the number of splash points, respectively. The qualified rates of ATP detection and microbial culture were 25% and 15%, respectively. Pseudomonas aeruginosa, Staphylococcus epidermidis, and other pathogenic bacteria were detected in the water outlet of the faucet and the surrounding environment. Safe hand hygiene facilities are one of the important guarantees of hand hygiene effect. Clean objects and objects related to patients should not be placed within 1 m range near the water outlet of faucet. Anti-splash baffle should be installed as much as possible when conditions permit to reduce the contaminate caused by splash during hand washing.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Hand Disinfection / Intensive Care Units Limits: Humans Language: En Journal: Sci Rep Year: 2024 Document type: Article Affiliation country: China Country of publication: United kingdom

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Hand Disinfection / Intensive Care Units Limits: Humans Language: En Journal: Sci Rep Year: 2024 Document type: Article Affiliation country: China Country of publication: United kingdom