Your browser doesn't support javascript.
loading
A highly sensitive spectrofluorimetric method for the determination of bilastine in human plasma: Application of content uniformity testing.
Omar, Mahmoud A; Khojah, Hani M J; Al Thagfan, Sultan S; Alolayan, Sultan Othman; Attia, Tamer Z.
Affiliation
  • Omar MA; Department of Pharmacognosy and Pharmaceutical Chemistry, College of Pharmacy, Taibah University, Al-Madinah Al-Munawwarah, Saudi Arabia.
  • Khojah HMJ; Analytical Chemistry Department, Faculty of Pharmacy, Minia University, Minia, Egypt.
  • Al Thagfan SS; Department of Pharmacy Practice, College of Pharmacy, Taibah University, Al-Madinah Al-Munawarah, Saudi Arabia.
  • Alolayan SO; Department of Pharmacy Practice, College of Pharmacy, Taibah University, Al-Madinah Al-Munawarah, Saudi Arabia.
  • Attia TZ; Department of Pharmacy Practice, College of Pharmacy, Taibah University, Al-Madinah Al-Munawarah, Saudi Arabia.
Luminescence ; 39(7): e4816, 2024 Jul.
Article in En | MEDLINE | ID: mdl-38965898
ABSTRACT
Bilastine, a new second generation antihistaminic drug, has been widely used for relieving symptoms of allergic rhinitis and urticaria without a sedative effect. A simple, cost-effective, and highly sensitive fluorimetric method was developed for the estimation of bilastine in human plasma, in addition to its pure state and tablets. The suggested method depended on binary complex formation of eosin with bilastine in a buffered medium at pH 4.2. The formed complex resulted in quantitative quenching of eosin emission at 538 nm after excitation at 335 nm. This method demonstrates a broad range of linearity, spanning from 200 to 1000 ng/mL, and exhibits exceptional sensitivity, with a limit of detection and quantitation of 30.85 and 93.48 ng/mL, respectively. In addition, this spectrofluorimetric method may be employed to determine the amount of bilastine in human plasma and tablets with satisfactory accuracy and excellent precision. Furthermore, the content uniformity of bilastine in commercially available tablets was successfully tested by this approach. Compared with the reference method, there were no significant variations in terms of precision or accuracy. In conclusion, the proposed protocol is highly recommended to quantitatively estimate bilastine in different quality control settings.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Piperidines / Spectrometry, Fluorescence / Tablets / Benzimidazoles Limits: Humans Language: En Journal: Luminescence Journal subject: BIOFISICA / BIOQUIMICA Year: 2024 Document type: Article Affiliation country: Saudi Arabia Country of publication: United kingdom

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Piperidines / Spectrometry, Fluorescence / Tablets / Benzimidazoles Limits: Humans Language: En Journal: Luminescence Journal subject: BIOFISICA / BIOQUIMICA Year: 2024 Document type: Article Affiliation country: Saudi Arabia Country of publication: United kingdom