Miniaturized 3D-printed hand-operable dispersive sample pretreatment device with replaceable chitosan/polydopamine thin film metal sorbent for enhanced metal analysis.
Arputharaj, Emmanuvel; Huang, Yu-Hui; Mariadoss, Arokia Vijaya Anand; Delattre, Cédric; Chen, Po-Chih; Huang, Yeou-Lih.
Affiliation
  • Arputharaj E; Department of Medical Laboratory Science and Biotechnology, Kaohsiung Medical University, Kaohsiung, Taiwan.
  • Huang YH; Department of Medical Laboratory Science and Biotechnology, Kaohsiung Medical University, Kaohsiung, Taiwan.
  • Mariadoss AVA; Orthopaedic Research Center, Kaohsiung Medical University, Kaohsiung, Taiwan.
  • Delattre C; Université Clermont Auvergne, Clermont Auvergne INP, CNRS, Institut Pascal, F-63000 Clermont-Ferrand, France; Institut Universitaire de France (IUF), 1 Rue Descartes, 7500 Paris, France.
  • Chen PC; Department of Laboratory Medicine, Kaohsiung Medical University Hospital, Kaohsiung Medical University, Kaohsiung, Taiwan.
  • Huang YL; Department of Medical Laboratory Science and Biotechnology, Kaohsiung Medical University, Kaohsiung, Taiwan; Department of Laboratory Medicine, Kaohsiung Medical University Hospital, Kaohsiung Medical University, Kaohsiung, Taiwan; Research Center for Precision Environmental Medicine, Kaohsiung Medi
Int J Biol Macromol ; 276(Pt 1): 133767, 2024 Sep.
Article in En | MEDLINE | ID: mdl-38986989
ABSTRACT
To address the increasing demand for sensitive and selective sample preparation methods for metal analysis; preconcentration of intended analyte from complex sample matrices before analysis is required to improve the performance of analysis instruments. In this study, we have engineered a sustainable and portable syringe-based hand-operable three-dimensionally (3D) printed sample pretreatment apparatus equipped with a replaceable bio-based thin- film metal sorbent. This device effectively addresses the challenges of sample matrix interference in metal analysis. A metal sorbent film composed of chitosan (CS) and polydopamine (PDA) leveraged the diverse functional groups in the CS/PDA matrix to significantly enhance the extraction efficiency for various metals. Our approach demonstrated excellent analytical performance, with coefficients of determination (R2) of 0.9982 for copper (Cu) and 0.996 for chromium (Cr). The method achieved low limits of detection (LOD) of 0.3 µg L-1 for Cr and 0.7 µg L-1 for Cu. Precision and practicality assessments using actual urine samples yielded satisfactory relative standard deviations (RSD%) ranging from of 1.6 %-8.5 % for both metals, indicating minimal interference from the sample matrix. Moreover, our approach exhibited robust performance even after seven consecutive extraction and desorption cycles, highlighting its sustainability and practical applicability for laboratory and on-site sample pretreatment.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Polymers / Chitosan / Printing, Three-Dimensional / Indoles Limits: Humans Language: En Journal: Int J Biol Macromol Year: 2024 Document type: Article Affiliation country: Taiwan

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Polymers / Chitosan / Printing, Three-Dimensional / Indoles Limits: Humans Language: En Journal: Int J Biol Macromol Year: 2024 Document type: Article Affiliation country: Taiwan