Ten-Year Clinical Outcomes of V4c Implantable Collamer Lens Implantation: Longitudinal Analysis of Visual Acuity, Endothelial Cell Density, and Vault Dynamics.
Chung, Byunghoon; Choi, Jin Young; Kang, David S Y; Kim, Kangyoon; Kim, Bo Yi; Kim, Tae-Im.
Affiliation
  • Chung B; From the Eyereum Eye Clinic (B.C., J.Y.C., D.S.Y.K., K.Y.K.), Seoul, Republic of Korea.
  • Choi JY; From the Eyereum Eye Clinic (B.C., J.Y.C., D.S.Y.K., K.Y.K.), Seoul, Republic of Korea.
  • Kang DSY; From the Eyereum Eye Clinic (B.C., J.Y.C., D.S.Y.K., K.Y.K.), Seoul, Republic of Korea.
  • Kim K; From the Eyereum Eye Clinic (B.C., J.Y.C., D.S.Y.K., K.Y.K.), Seoul, Republic of Korea.
  • Kim BY; Corneal Dystrophy Research Institute, Department of Ophthalmology (B.Y.K., T.K.), Yonsei University College of Medicine, Seoul, Republic of Korea.
  • Kim TI; Corneal Dystrophy Research Institute, Department of Ophthalmology (B.Y.K., T.K.), Yonsei University College of Medicine, Seoul, Republic of Korea; Department of Material Science and Engineering (T.K.), Yonsei University, Seoul, Republic of Korea; Affiliate faculty, Materials Research Center for Batt
Am J Ophthalmol ; 269: 1-10, 2024 Aug 13.
Article in En | MEDLINE | ID: mdl-39142448
ABSTRACT

PURPOSE:

This study aimed to evaluate the long-term clinical outcomes of V4c Implantable Collamer Lens (ICL) implantation for myopia correction over a 10-year period.

DESIGN:

Retrospective interventional case series

METHODS:

This retrospective interventional study involved 103 myopic eyes from 54 patients. Visual outcomes, including visual acuity and manifest refraction were assessed. Annual measurements of endothelial cell density (ECD), vault, anterior chamber depth, and intraocular pressure were analyzed using mixed-effects models.

RESULTS:

At the 10-year follow-up, the mean Logarithm of the Minimum Angle of Resolution (logMAR) uncorrected distance visual acuity and corrected distance visual acuity (CDVA) were -0.037 ± 0.052 and -0.041 ± 0.046, respectively. The mean efficacy and safety indices were 1.11 ± 0.13 and 1.12 ± 0.12. A loss of one line of CDVA occurred in 2% of cases, while 59% gained one or more lines. Postoperative manifest refraction spherical equivalent (MRSE) was within ±0.5 diopters (D) and ±1.0 D in 74% and 99% of cases, respectively, with a mean MRSE of -0.19 ± 0.41 D. Data for ECD and vault fit an exponential decay model, demonstrating a continuous yet gradually slowing decrease over time. Decay rates were 0.012 ± 0.001 per year for ECD and 0.056 ± 0.003 per year for the vault. Notably, ECD lower outliers had significantly lower preoperative ECD values. There were no instances of cataract formation, angle closure, glaucoma, or ICL removal throughout the study.

CONCLUSIONS:

The 10-year outcomes of V4c ICL implantation demonstrate effective and safe visual results. Both ECD and vault exhibit exponential decay patterns over the decade. Patients with lower preoperative ECD values require careful post-implantation monitoring.

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Am J Ophthalmol Year: 2024 Document type: Article Country of publication: United States

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Am J Ophthalmol Year: 2024 Document type: Article Country of publication: United States