Your browser doesn't support javascript.
loading
Analysis of human biological samples using porous graphitic carbon columns and liquid chromatography-mass spectrometry: a review.
Rodrigues, Taís Betoni; Cunha, Ricardo Leal; Barci, Paulo Emílio Pereira; Santos-Neto, Álvaro José; Lanças, Fernando Mauro.
Affiliation
  • Rodrigues TB; Laboratory of Chromatography (CROMA), São Carlos Institute of Chemistry, University of São Paulo (USP), São Carlos, São Paulo, 13560-970, Brazil. tais.betoni.rodrigues@usp.br.
  • Cunha RL; Forensic Toxicology Laboratory, Scientific Police, São Cristóvão, Sergipe, 49100-000, Brazil.
  • Barci PEP; Laboratory of Chromatography (CROMA), São Carlos Institute of Chemistry, University of São Paulo (USP), São Carlos, São Paulo, 13560-970, Brazil.
  • Santos-Neto ÁJ; Laboratory of Chromatography (CROMA), São Carlos Institute of Chemistry, University of São Paulo (USP), São Carlos, São Paulo, 13560-970, Brazil.
  • Lanças FM; Laboratory of Chromatography (CROMA), São Carlos Institute of Chemistry, University of São Paulo (USP), São Carlos, São Paulo, 13560-970, Brazil.
Anal Bioanal Chem ; 2024 Aug 19.
Article in En | MEDLINE | ID: mdl-39158631
ABSTRACT
Liquid chromatography-mass spectrometry (LC-MS) has emerged as a powerful analytical technique for analyzing complex biological samples. Among various chromatographic stationary phases, porous graphitic carbon (PGC) columns have attracted significant attention due to their unique properties-such as the ability to separate both polar and non-polar compounds and their stability through all pH ranges and to high temperatures-besides the compatibility with LC-MS. This review discusses the applicability of PGC for SPE and separation in LC-MS-based analyses of human biological samples, highlighting the diverse applications of PGC-LC-MS in analyzing endogenous metabolites, pharmaceuticals, and biomarkers, such as glycans, proteins, oligosaccharides, sugar phosphates, and nucleotides. Additionally, the fundamental principles underlying PGC column chemistry and its advantages, challenges, and advances in method development are explored. This comprehensive review aims to provide researchers and practitioners with a valuable resource for understanding the capabilities and limitations of PGC columns in LC-MS-based analysis of human biological samples, thereby facilitating advancements in analytical methodologies and biomedical research.