Your browser doesn't support javascript.
loading
Micro-osteoperforation for enhancement of orthodontic movement: A mechanical analysis using the finite element method.
Gomes, João Ricardo Cancian Lagomarcino; Vargas, Ivana Ardenghi; Rodrigues, Antônio Flávio Aires; Gertz, Luiz Carlos; Freitas, Maria Perpétua; Miguens, Sergio Augusto Quevedo; Ozkomur, Ahmet; Hernandez, Pedro Antonio González.
Affiliation
  • Gomes JRCL; Graduate Program in Dentistry, Universidade Luterana do Brasil (ULBRA), Canoas, RS, Brazil.
  • Vargas IA; School of Dentistry, Universidade Luterana do Brasil (ULBRA), Canoas, RS, Brazil.
  • Rodrigues AFA; Graduate Program in Dentistry, Universidade Luterana do Brasil (ULBRA), Canoas, RS, Brazil.
  • Gertz LC; School of Mechanical Engineering, Universidade Luterana do Brasil (ULBRA), Canoas, RS, Brazil.
  • Freitas MP; Graduate Program in Dentistry, Universidade Luterana do Brasil (ULBRA), Canoas, RS, Brazil.
  • Miguens SAQ; Graduate Program in Dentistry, Universidade Luterana do Brasil (ULBRA), Canoas, RS, Brazil.
  • Ozkomur A; Graduate Program in Dentistry, Universidade Luterana do Brasil (ULBRA), Canoas, RS, Brazil.
  • Hernandez PAG; Graduate Program in Dentistry, Universidade Luterana do Brasil (ULBRA), Canoas, RS, Brazil.
PLoS One ; 19(8): e0308739, 2024.
Article in En | MEDLINE | ID: mdl-39159186
ABSTRACT

BACKGROUND:

Micro-osteoperforation is a minimally invasive technique aimed at accelerating tooth movement. The goal of this novel experimental study was to assess tooth movement and stress distribution produced by the force of orthodontic movement on the tooth structure, periodontal ligament, and maxillary bone structure, with and without micro-osteoperforation, using the finite element method. MATERIALS AND

METHODS:

Cone-beam computed tomography was used to obtain a virtual model of the maxilla and simulate the extraction of right and left first premolars. Three micro-osteoperforations (1.5 x 5 mm) were made in the hemiarch on the distal and mesial surfaces of upper canines, according to the power tip geometry of the Propel device (Propel Orthodontics, Ossining, New York, USA). An isotropic model of the maxilla was fabricated according to the finite element method by insertion of mechanical properties of the tooth structures, with orthodontic force (1.5 N) simulation in the distal movement on the upper canine of a hemiarch.

RESULTS:

Initial movement was larger when micro-osteoperforations were performed on the dental crown (24%) and on the periodontal ligament (29%). In addition, stress distribution was higher on the bone structure (31%) when micro-osteoperforations were used.

CONCLUSIONS:

Micro-osteoperforations considerably increased the movement of both the dental crown and periodontal ligament, which highlights their importance in the improvement of orthodontic movement, as well as in stress distribution across the bone structure. Important stress absorption regions were identified within micro-osteoperforations.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Periodontal Ligament / Tooth Movement Techniques / Finite Element Analysis Limits: Humans Language: En Journal: PLoS One Journal subject: CIENCIA / MEDICINA Year: 2024 Document type: Article Affiliation country: Brazil Country of publication: United States

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Periodontal Ligament / Tooth Movement Techniques / Finite Element Analysis Limits: Humans Language: En Journal: PLoS One Journal subject: CIENCIA / MEDICINA Year: 2024 Document type: Article Affiliation country: Brazil Country of publication: United States